Uni-P Pro 200X Dehumidifier

Troubleshooting

Symptom
Poor Connection
Display is Blank
No Airflow
Air Inlet or Outlet
Humidity Sensor or
Error Code:E1
Communication Error
Error Code:E4
Problem with Pump
Room Temperature
Error Code:LO
Error Code:HI
Room Temperature
is above 105℉
Not a Dedicated Circuit
Defective GFCI Outlet
Tripped GFCI
Outlet or Breaker
Moisture on Outlet
Lightning or Externa
Electrical Surge
Possible Dehumidifier
Tel: 888-990-7469
Installation, Operation & Service Instructions
Cause
Solution
Verify that both ends of the
cord are plugged in
Power Outage
Reset power
Filter is dirty
Clean the Filter
Clean the blockage
is Blocked
Check to ensure that the sensor wire
is connected at both ends. if no issues
are visible, the sensor may be faulty.
Verify that the pump is properly
installed and functioning. If so, unplug
the unit for two minutes,then restart.
Increase the room temperature so it is
within operating range (above 33℉). If
is below 33℉
error still displays, check sensor.
Decrease the room temperature so it is
within operating range (below 105℉).
If error stille displays, check the
sensor
Identify all sources connected to outlet
and confirm source of trip.If it is
dehumidifier, contact technical
support. If not, move dehumidifier to
dedicated circuit for future use.
Replace Outlet
Dirt, Dust, or
Clean or Replace Outlet as necessary
Reset or Replace Breaker/GFCI, as
necessary
If none of above options work, contact
Issue
technical support
10
Uni-P Pro 200X Dehumidifier
Pump Alarm- E4 Error Code
**UNIT WILL NOT FUNCTION UNTIL ERROR CODE IS CLEARED.
If E4 (pump alarm) is shown on the display, complete the following steps:
1. Reset the unit by unplugging the power cord and then reconnecting it.
2. Manually check to see if the pump is operational by pressing the drain button. Check
if the pump energizes and de-energizes properly. Additionally, check to see if any water
purged from the system.
3. If you haven't cleaned the system recently, check the discharge line for an obstruction,
then clean as described in the Maintenance section.
4. Replace the hose and/or pump, if maintenance alone isn't sufficient.

Spare Parts

Display/Control
N-100
Main Control Board
N-101
Display Board
N-102
RH/Temp. Sensor
Inernal Components
Compressor
N-1209
N-1206
Compressor Capacitor
N-1208
Coil Assembly
Condensate Pump
N-1207
Assembly
11
Installation, Operation & Service Instructions
Fan Components
N-1210
Fan Motor
Complete Fan Assembly
N-1211
N-1205
Fan Capacitor
Filter + External Components
N-1200
Prefilter
N-1201
MERV 8
N-1202
HEPA
N-1203
Carbon Filter
Foot adjustable
N-125
Cables
N-120
Temp/RH Sensor Cable
Display Ribbon Cable
N-121
N-122
CaТ: 5 Port Internal Cable
Duct + Ventilation Accessories
Supply Duict Collar
N-1204
Assembly
Tel: 888-990-7469

Advertisement

Table of Contents
loading

Table of Contents