Rear Panel Call-Outs - Wharfedale Pro Titan Sub A15 Owner's Manual

Professional active subwoofer system
Hide thumbs Also See for Titan Sub A15:
Table of Contents

Advertisement

Titan Sub-A15 – REAR PANEL CALL-OUTS
1. INPUT A - Balanced line level input via a XLR / ¼" combo connection.
2. OUTPUT A - Balanced male XLR connection provides output "THRU" or HIGHPASS signal
(depending on switch setting).
3. SPEAKER LEVEL INPUT -
Allows for connection of the output of an external amplifier to use the Titan Sub-A15 as a passive
subwoofer.
NOTE: Disconnect the power cord when using the Titan Sub-A15 in this mode.
4. INPUT B - Balanced line level input via a XLR / ¼" combo connection.
5. OUTPUT B - Balanced male XLR connection provides output "THRU" or HIGHPASS signal
(depending on switch setting).
6. HEATSINK - Cooling fins for amplifier. Do not obstruct.
7. VOLUME CONTROL - Adjusts volume level of the subwoofer.
1
INPUT A
OUTPUT A
2
SPEAKER
3
LEVEL INPUT
4
INPUT B
5
OUTPUT B
8. THRU / HIGHPASS SWITCH - Selects the signal type that is routed to the OUTPUT jacks. "THRU" sends
9. PHASE SWITCH - Selects the polarity of the signal being sent to the subwoofer. 0° selects the signal
10. LIMIT LED – LED indicator illuminates when the signal limiting function is activated.
11. POWER LED - LED indicator illuminates when the unit is powered up.
12. POWER SOCKET - This is the connection for the IEC AC power connector.
13. POWER SWITCH – Turns the power on and off to the subwoofer amplifier module.
OUTPUT
INPUT
(BALANCED)
(BALANCED)
A
THRU
(100Hz)
HIGHPASS
SPEAKER
LEVEL IN
B
(BALANCED)
(BALANCED)
INPUT
OUTPUT
SERIALNUMBER
the unprocessed signal to the outputs. "HIGHPASS" filters the signal and
only sends signals above 100Hz to the outputs.
polarity as it appears at the input. The "180°" selection inverts the phase of the signal.
0
_
WWW.WHARFEDALEPRO.COM
MAX
VOLUME
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING: SHOCK HAZARD
DO NOT OPEN
180°
AVIS: RISQUE DE CHOC ELECTRIQUE
-NE PAS OUVRIR
PHASE
N 2082
LIMIT
ON
OFF
POWER
AC 220-240V~50Hz 400W
FUSE T4AL250V
7
HEATSINK
VOLUME
CONTROL
THRU / HIGHPASS
SWITCH
!
PHASE SWITCH
LIMIT LED
POWER LED
POWER SOCKET
POWER SWITCH
6
7
8
9
10
11
12
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Titan sub-a15

Table of Contents