Eastwood 31915 Instructions Manual page 4

29 gallon single stage air compressor
Table of Contents

Advertisement

COMPRESSOR SET UP
Compressor Break-In Procedure
The initial, new compressor break-in procedure
must be performed for best performance & maximum pump life.
To do so:
1. Check the oil level (see maintenance section on page 6).
2. Open the Water Drain Valve located at the underside of the
Tank (Fig 1).
3. Make sure the Power Switch is in the "OFF" position (Fig 2).
4. Plug the Power Cord into an appropriate 120 VAC, 15 Amp
minimum, grounded receptacle.
5. Move Power Switch to the "ON/AUTO" position (Fig 2).
6. Allow the Compressor to run for 10 minutes. Air and
manufacturing oil will discharge freely from the Water
Drain Valve.
7. After 10 minutes, move the Power Switch to the "OFF"
position (Fig 2) and unplug the Power Cord.
8. Close the Water Drain Valve (Fig 1).
9. Inspect the entire system including crankcase, cylinders
and hard lines for any evidence of oil leaks.
10. With the Water Drain and Air Outlet Valves closed, plug the
unit back in, turn the Power Switch to "ON/AUTO", allow
full pressure to build, once again, turn the Power Switch to
"OFF" (Fig 2).
11. Listen for any air leakage and observe the crankcase, all
lines and fittings for any evidence of oil leakage.
12. The Eastwood 29 Gallon Compressor is now ready for use.
COMPRESSOR LOCATION
Positioning
The Eastwood 29 Gallon Compressor generates heat during operation and
has a highly efficient air-cooled system. Sufficient space must be provided around the unit
for cooling air circulation.
1. Locate the Air-Intake Grill no less than 1 ft. [.3m] away from any wall or enclosure.
2. Locate the sides and front of the Compressor no less than 1 ft. [.3m] away from any
wall or enclosure.
3. Maintain at least 2 feet [.6m] of free space above the Compressor.
To provide proper ventilation for cooling and prevent
overheating, the compressor must be kept a minimum of 12 inches (31 cm)
from the nearest wall, in a well–ventilated area. DO NOT allow the Cover
ventilation holes to be blocked or possible permanent damage could occur.
Air Line Connection
The Eastwood 29 Gallon Compressor is designed with a convenient, pre-installed 3/8" Female Quick-Disconnect at the air outlet and is
compatible with most 1/4" NPT, 3/8" Male Quick Disconnect fittings (Fig 3).
To utilize the maximum performance from the Compressor, it is strongly recommended to use 3/8" or larger air lines and fittings throughout your system. The use
of less than 3/8" lines will greatly hamper performance.
In order to protect valuable air tools and equipment and prevent contamination It is strongly advisable to use a suitable, high efficiency Moisture/Oil Separator
(not included) in a well-planned airline layout after the Air Outlet.
4
FIG. 1
Close
FIG. 2
Pressure
Release
FIG. 3
Eastwood Technical Assistance: 800.544.5118 >> techelp@eastwood.com
Open
Off
On/Auto
Increase
Regulator
3/8" Quick
Disconnect
Decrease

Advertisement