SAFETY INFORMATION
• This unit starts automatically. ALWAYS shut off the compressor, remove the plug from the outlet, and bleed all pressure from the tank
before servicing the compressor, and when the compressor is not in use.
• Fan Blade can start at any time. To help avoid personal injury, keep hands clear.
• Do not use the unit with the Cover removed. Severe injury could occur from contact with moving parts.
• Never direct high-pressure airstream to exposed flesh.
• This compressor must be located only on a flat, level and secure surface. Do not locate the compressor on an elevated platform, table,
bench, roof or other non-secure location
• The Pump generates heat during operation. Use caution when servicing to avoid burns.
• Always wear ANSI Z87 approved eye protection when operating this compressor and associated equipment. Air, moisture and debris
can be ejected at high velocity while using this equipment.
• Air discharged from this compressor is not intended for and should never be used as supply air for human consumption.
• The Tank is labeled with a U.S. Consumer Product Safety Commission mandated expiration date for pressure vessels based on date of
manufacture. Operating the Tank beyond the posted expiration date subjects the user to a Bursting Hazard.
• DO NOT operate the Compressor beyond the posted date without having the tank pressure tested at an approved compressed air tank
testing facility. Internal rust and metal fatigue from long term use can severely impair tank strength and cause an extremely hazardous
condition.
• Touching the Pump while running and for a considerable time afterward will cause burns.
• Use caution when servicing to avoid burns.
• Check the manufacturer's maximum pressure rating for air tools and accessories. Compressor outlet pressure must be regulated to
never exceed the maximum pressure rating of the tool. Relieve all pressure through the hose before attaching or removing accessories.
• Do not adjust the Pressure Relief Valve for any reason. The Pressure Relief Valve has been pre-set at the factory for the maximum safe
pressure of this unit. Personal injury and/or property damage may result if the relief valve is tampered with.
• Use only hose, pipe and fittings rated for compressed air distribution lines. Do Not use plastic or PVC pipes.
• Do not weld, drill or modify the air tank of this compressor. Welding or modifications on the air compressor tank can severely impair
tank strength and cause an extremely hazardous condition.
To order parts and supplies: 800.345.1178 >> eastwood.com
INJURY HAZARD!
BURN HAZARD!
EYE INJURY HAZARD!
HEALTH HAZARD!
BURN HAZARD!
BURST HAZARD!
Drain the moisture from the tank daily. An empty, moisture free tank will help prevent internal corrosion & prolong tank life.
To provide proper ventilation for cooling and prevent overheating, the compressor must be kept a minimum of 12 inches
(31 cm) from the nearest wall, in a well–ventilated area. DO NOT allow the Belt Guard to be blocked or possible
permanent damage could occur.
Pull the Pressure Relief Valve ring daily to test that the valve is functioning properly, & to clear the valve of any obstructions.
REQUIRES 120 VAC, 13.8 AMP, 60Hz.
the warranty will be void if not performed by a licensed electrician.
This unit is equipped with a Grounded Plug. It may be hardwired, however
3