4.4.3

Deactivation

By pressing the two buttons simultaneously for more than 3
seconds, the ON Mode and therefore the Rescue Transmitter
can be switched off. For quitting TEST mode, press button
TEST for more than 3 seconds.
Otherwise the Rescue Transmitter continues to operate until
the battery is flat. (In test mode, the device switches off
automatically. See chapter 4.5)
(Only applies to devices with magnetic triggering:
A fast blinking TEST LED indicates that the Rescue Transmitter
is switched off and that the magnetic release was not
triggered. In this case sending emergency signals stops. By
inserting the magnet, the flashing of the LED stops and the
device switches off automatically.)
General rule:
The device must be serviced by an authorized service center
after activation.
4.5

TEST Mode

A function test can be carried out 30 times within the period
of five years until the battery needs to be replaced as
stipulated by SOLAS. This does not impair the operation of 96
hours (AIS operation) or 24 hours (AIS & DSC operation) in the
event of an activation.