N O T E
N O T E
N9360A Multi UE Tester GSM Programming Manual
ORFS Limit Type
CONFigure:CONDition:LIMit:ORFS:TYPE GMSK|PSK
CONFigure:CONDition:LIMit:ORFS:TYPE?
This command sets modulation type for high limit of ORFS
Modulation / Switching test for Radio System that is being
selected. The parameter is GMSK or PSK. This is valid only when
GSM mode is set EGPRS. This serves as an execution error when
GSM mode is set GSM or GPRS. (In this case, the query command
is only valid.). At preset, this is set to GMSK.
Thise command is valid at corresponding GSM mode (GSM, GPRS,
EGPRS)
Signaling Pattern
CONFigure:CONDition:SIGNalingpattern <int>
CONFigure:CONDition:SIGNalingpattern?
This command sets signaling pattern. The allowable range is
from 1 to 255. At preset, this is set to 1.
This command is valid when the GSM mode is set to EGPRS.
Power Ramp Template
CONFigure:CONDition:LIMit:RAMP:MASK:PCS
NARRow|RELaxed
CONFigure:CONDition:LIMit:RAMP:MASK:PCS?
This command sets template type of Power Ramp measuremnt
for PCS1900. The parameter is NARRow or ELaxed. At preset,
this is set to NARRow. If RELaxed is set, the template is selected
same one for DCS1800. This setting is initialized to NARRow at
power on.
Programming Command Reference
5
5-77