Agilent Technologies N9360A Programming Manual page 122

Multi ue tester, gsm programming
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

Programming Command Reference
5
5-64
BER BS Level
CONFigure:CONDition:SENSitivity:LEVel <real>
CONFigure:CONDition:SENSitivity:LEVel?
This command sets the amplitude (BS Level) of the output
signal from the Tester for error ratio tests, for each radio system
set by the
Radio System
The allowable range is from -110.0 to -50.0 dBm in 0.1
steps. At preset, this is set to -102.0 dBm for GSM850, GSM900
and PCS1900, or -100.0 dBm for DCS1800.
This query command returns the set amplitude of output signal
for error ratio tests with real. The range of the value is same as
that of the command parameter.
BER Frames
BER (GSM Mode, Test Mode A)
CONFigure:CONDition:SENSitivity:FRAMe <int>
CONFigure:CONDition:SENSitivity:FRAMe?
FAST BER (GSM Mode, Test Mode C)
CONFigure:CONDition:SENSitivity:FRAMe:BERFast
<int>
CONFigure:CONDition:SENSitivity:FRAMe:BERFast?
BER (GPRS Mode, Test Mode B)
CONFigure:CONDition:SENSitivity:FRAMe:BERGprs
<int>
CONFigure:CONDition:SENSitivity:FRAMe:BERGprs?
BLER (GPRS/EGPRS Test Mode ACK)
CONFigure:CONDition:SENSitivity:FRAMe:BLER <int>
CONFigure:CONDition:SENSitivity:FRAMe:BLER?
command described on
N9360A Multi UE Tester GSM Programming Manual