Single Slot Dock Locking LED Indicators
LED
Power On (Green LED)
Solid green for 3 seconds
Short blink every few seconds
Off
Battery Charger LED (Bicolor Green/Red LED)
Off
Solid red
Solid green
Maintenance LED (Red LED)
Blink red, 1 quick pulse
Blink red, 2 quick pulses
User's Manual
Dock bootstrap: cradle application started.
Dock standby (if the standby LED is
enabled): the dock is powered and ready, no
device inserted. You can enable/disable
the standby LED feature from DL Cradle
Manager.
Dock standby (if the standby LED is
disabled): the dock is powered and ready,
no device inserted. You can enable/disable
the standby LED feature from DL Cradle
Manager.
Device not charging or not inserted (see
above).
Device is charging.
Device charging completed.
Cradle not calibrated. Solution: perform an
"auto calibration" from DL Cradle Manager.
Ensure that levers are free to move.
Lever wrong position. It is open but it
should be closed or vice versa. Solution:
restore the lever position (e.g.remove the
mechanical key from the slot).