Q U I C K S T A R T G U I D E
KEPCO
I — INTRODUCTION
SCOPE OF MANUAL This Quick Start Guide covers
the installation and operation of the Kepco HSP Series of
voltage and current stabilized d-c power supplies. Full
specifications are listed in the applicable Operator's Man-
ual that can be downloaded from the Kepco web site at
www.kepcopower.com/support/opmanls.htm/#hsp
FACTORY DEFAULTS This guide covers only units as
shipped from the factory with the three DIP switches set to
default configuration (see Figure 1). For other configura-
tions, refer to HSP Operator Manual.
DESCRIPTION The HSP power supply (Figure 1-1) is
basically a voltage and current stabilized d-c source with a
relatively sharp crossover between voltage and current
mode operation.
HSP power supplies are nominally rated at either 1000 or
1500 Watts of output power, and include active power fac-
tor correction (PFC). HSP 1000W power supplies are
designed to operate over the universal a-c power mains
voltage range of 90-277V (47-63Hz), with operation from
125-420V d-c also available. HSP 1500W products provide
full power over the a-c mains range of range of 180-277V
a-c, and 1000W output power from 90-132V a-c; contact
Kepco for information on operation over other source volt-
age ranges. Cooling is provided via an internal d-c fan.
HSP permits adjustment of both output voltage (V
current limit (I
), either by internal (front panel pot) or
MAX
external (resistance or voltage) methods, selected via DIP
switches accessed through the top of the unit. Protection
against overvoltage, overcurrent and overtemperature fail-
ures is provided.
(1)
MODELS
3.3V
1000W
HSP 3.3-230R
1500W
N/A
(1) Options include suffix M or B: M for meter; B for battery charger
(2) CE Marked, Not UL listed.
KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102
©2020, KEPCO, INC
Data subject to change without notice
An ISO 9001 Company.
SINGLE OUTPUT
PROGAMMABLE POWER SUPPLIES
) and
O
TABLE 1. HSP SERIES MODELS
5V
12V
HSP 5-200R
HSP 12-84R
N/A
N/A
www.kepcopower.com   email: hq@kepcopower.com
228-1706 REV 2
FIGURE 1. DIP SWITCH FACTORY DEFAULTS
The HSP power supply is specifically designed for use with
Kepco RA 60 or similar plug-in rack adapters as a hot
replaceable module in a redundant power system. Bench
top operation is also supported. Forced current sharing and
output blocking diodes enhance power system reliability.
Mechanical keying eliminates the risk of incorrect module
insertion. Tool-operated latches on the front panel guard
against casual removal of an operating module.
OPTIONS M models include a digital meter which dis-
plays either voltage or current as determined by a front
panel switch. Another switch allows display of either
actual HSP Output or the setpoint. B models are intended
for battery charging applications, and include a Float/
Equalize switch to preset two different voltage values
using two separate front panel adjustment pots.
15V
24V
HSP 15-66R
HSP 24-42R
N/A
HSP 24-60R
HSP
1000W/1500W
28V
48V
HSP 28-36R
HSP 48-21R
HSP 28-53R
HSP 48-30R
125V
(2)
HSP 125-8R
(2)
HSP 125-12R
1

Advertisement

loading

Summary of Contents for KEPCO HSP Series

  • Page 1 (1) Options include suffix M or B: M for meter; B for battery charger (2) CE Marked, Not UL listed. KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 www.kepcopower.com   email: hq@kepcopower.com ©2020, KEPCO, INC...
  • Page 2 OFF circuit breaker on front panel to ON. If actuator set (Kepco P/N 118-0776) or using a custom linecord KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 www.kepcopower.com   email: hq@kepcopower.com...
  • Page 3 62% of the maximum programmable current. For the low voltage. Current mode is maintained indefinitely, and recov- KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 www.kepcopower.com   email: hq@kepcopower.com...
  • Page 4 Adjust pot Used to adjust current limit from 3043522 front panel. FIGURE 4. COMPONENT LOCATIONS KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 www.kepcopower.com   email: hq@kepcopower.com 228-1706 REV 2 071520...

This manual is also suitable for:

Hsp 3.3-230rHsp 5-200rHsp 12-84rHsp 15-66rHsp 24-42rHsp 28-36r ... Show all