PureLink HX-4400S Owner's Manual

PureLink HX-4400S Owner's Manual

4x4 hdmi/vga integrated matrix switcher with scaling, multi-view, and video wall function

Advertisement

Quick Links

Owner's Manual
HX-4400S
4x4 HDMI/VGA Integrated Matrix Switcher with
Scaling, Multi-View, and Video wall Function
TM
PureLink
535 East Crescent Avenue
Ramsey, NJ 07446
USA
Tel: +1.201.488.3232
Fax: +1.201.621.6118
E-mail:
sales@purelinkav.com
www.purelinkav.com
For order support, please contact your local dealer.
For technical support, please contact us at
support@purelinkav.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HX-4400S and is the answer not in the manual?

Questions and answers

Summary of Contents for PureLink HX-4400S

  • Page 1 Owner’s Manual HX-4400S 4x4 HDMI/VGA Integrated Matrix Switcher with Scaling, Multi-View, and Video wall Function PureLink 535 East Crescent Avenue Ramsey, NJ 07446 Tel: +1.201.488.3232 Fax: +1.201.621.6118 E-mail: sales@purelinkav.com www.purelinkav.com For order support, please contact your local dealer. For technical support, please contact us at...
  • Page 2: Table Of Contents

    PureLink by Dtrovision ABLE OF ONTENTS Chapter 1. Product Overview & Specification 1.1 Safety Precautions --------------------------------------------------------------- 1.2 Declaration of Conformity --------------------------------------------------------------- 1.3 What’s in the Box --------------------------------------------------------------- 1.4 Product Introduction --------------------------------------------------------------- 1.5 Product Specification --------------------------------------------------------------- 1.6 Front View --------------------------------------------------------------- 1.7 Rear View --------------------------------------------------------------- 1.8 IR Remote Control...
  • Page 3: Safety Precautions

    PureLink by Dtrovision Chapter 1. Introduction 1.1 Safety Precautions  All safety instructions should be read and understood before the unit is operated.  The owner’s manual and safety instructions should be retained for future reference.  Unplug this unit from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp cloth only.
  • Page 4: Declaration Of Conformity

    Council Directive Low Voltage Equipment Safety. Each product marketed is identical to the representative unit tested and found to be compliant with the standards. 1.3 What’s in the Box  Main Frame: HX-4400S  Power Adapter – DC 12V, 2.5A  4 x IR Tx cable ...
  • Page 5: Product Introduction

    The new HX-4400S HDMI/VGA Integrated Matrix Switcher with Scaling provide switching for up to four (4) HDMI or four (4) VGA inputs to any four (4) HDMI outputs with PureLink’s legendary don’t blink instantaneous switching technology. With built-in scaler, it features various seamless switching modes, video wall and Multiview output functions.
  • Page 6 PureLink by Dtrovision  19” standard rack type case (1U) Multiview function There are 4 layout modes for multi view function Mode 1: Mode 2:...
  • Page 7 PureLink by Dtrovision Mode 3: Mode 4:...
  • Page 8 PureLink by Dtrovision Video wall function <Original Input Image> <Videowall splitted image to 4 displays>...
  • Page 9: Product Specification

    PureLink by Dtrovision 1.5 Product Specifications HX-4400S General Specification Power External Power Supply DC12V, 2.5A (US/EU standards, CE/FCC/UL certified) Operational Temperature 32° ~ 117° F (0° to 47° C) Storage Temperature - 40° ~ 158° F (-40° to 70° C)
  • Page 10: Front View

    4 x IR output 1.6 Front View of HX-4400S The HX-4400S chassis is mountable on 19” standard rack with brackets. On front panel, there are some function keys, input-output buttons and a status display window placed as shown in Figure 1-1.
  • Page 11: Rear View

    1.7 Rear View of HX-4400S <Back Panel> (Figure 1-2) 1 IR IN/OUT: IR port for HX-4400S control, IR Inputs, and IR outputs 2 Analog Input: VGA , Composite, and 3.5mm stereo audio inputs 3 Control Interface: LAN (TCP/IP) and RS232 control ports...
  • Page 12: Ir Remote Control

    PureLink by Dtrovision 1.8 IR remote control 1. Power On/Off button 2. Output selection buttons A – Output 1 B – Output 2 C – Output 3 D – Output 4 3. Input selection buttons 1 – Input 1 2 – Input 2 3 –...
  • Page 13: Installation Guidelines

    PureLink by Dtrovision 1.10 Installation Guidelines The following installation settings are recommended for optimal performance.  Operational temperature should be 30° C or below  Operational humidity should be 60% or below  Operational environment should be dust-free and well ventilated ...
  • Page 14: Communication Settings

    PureLink by Dtrovision 1.11 Communication Settings (LAN and RS232) Default RS232 communication parameters: Baud rate: 115200 Data bit: 8 bits Stop bit: 2 bits Parity: none Default LAN communication parameters: IP address: 192.168.0.100 Mac address: 0x00,0x15,0x09,0x22,0x4c,0x87...
  • Page 15: Chapter 2. Communication Code Configuration

    This section is designed for programmers who wish to create their own control programs using the command code. All PureLink digital matrix routers provide a simple character stream control used by external control devices attached to a PureLink device. Command codes are used primarily for control, during system installation and setup, and for diagnostic purposes.
  • Page 16: General Rules For Command Codes

    PureLink by Dtrovision 2.4 General Rules for Command Codes The commands are coded in ASCII and HEXA. Please refer to Table 2.1 on pg. 17 for detailed descriptions of keys and functions. A basic command code setup is shown below;...
  • Page 17: Command Ack Value Response

    PureLink by Dtrovision Table 2.1 Command Codes Characters Table The table below shows command code characters (keys), which are used to generate control commands, their functions, and short function descriptions. Function Description and Example Byte ASCII 0x2A Start the command...
  • Page 18: Connecting Switches

    PureLink by Dtrovision Router ID Error Indicates that the wrong ID number was entered Command Code Ack Value Examples Command Code Ack Value as appears in the control Explanation of Result Entered program *999CI01O01!  *255sC I01O01 ! The command was successfully executed The command was not executed because *999CO01! ...
  • Page 19: Disconnecting Switches

    PureLink by Dtrovision *999CI01O01-04!  Connect Input 1 to Output 1, 2, 3, and 4 *999PTP!  Connect Input 1 to Output 1, Input 2 to Output 2, Input 3 to Output 3 and Input 4 to Output 4 2.7 Disconnecting Switches The characters and numbers in a Disconnect command tell the system which input or output to disconnect.
  • Page 20 PureLink by Dtrovision Front panel buttons Lock Off  *999lockoff! Power on  *999poweron! Power off  *999poweroff! Factory setting restore  *999restore! Reboot  *999reboot! Output resolution setting  *999resolution1! 1 = 1080p 2 = 720p 3 = 1280x1024 4 = 1360x768 5 = 1024x768 Output mode setting ...
  • Page 21: Connection Status Check

    PureLink by Dtrovision Video wall horizontal value setting  *999vwx10! Value range : 1 – 32 Video wall vertical value setting  *999vwy10! Value range : 1 – 32 Output seamless mode setting  *999o01sm1! Seamless mode type : 1 – 16 Output seamless complete time setting ...
  • Page 22 PureLink by Dtrovision Output mode status  *999?mode! Mtx = matrix MV = multi viewer VM = video wall Multi view mode (POP) status  *999?pop! 1 = mode 1 2 = mode 2 3 = mode 3 4 = mode 4 Muti view (POP) main video setting status ...
  • Page 23: Chapter 3. Additional Information

    (3) year from the date of purchase from PureLink or its authorized resellers. If the product does not operate as warranted during the applicable warranty period, PureLink shall, at its option and expense, execute one of the following as necessary: 1.

Table of Contents