Inter-m PMC-6208 Operation Manual

Inter-m PMC-6208 Operation Manual

Program manual controller

Advertisement

Quick Links

Operation
anual
Program Manual ontroller
PM -6208
*Rack mount products in the Western Hemisphere (North merica, South merica,
and the Caribbean) do not have handles installed due to customer preference.

Advertisement

Table of Contents
loading

Summary of Contents for Inter-m PMC-6208

  • Page 1 Operation anual Program Manual ontroller PM -6208 *Rack mount products in the Western Hemisphere (North merica, South merica, and the Caribbean) do not have handles installed due to customer preference.
  • Page 2 Welcome personal welcome to you from the management and employees of Inter-M ll of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products.
  • Page 3: Table Of Contents

    ............................2 Installation Environment............................2 Important Safety Instructions......................2 Features ............................3 Contents and ccessories.........................3 Front Panel ............................4 Rear Panel ............................5 Operation ............................7 pplications ..........................11 Block Diagram ..........................12 Specifications ..........................13 Service Procedures............................14 Schematic .............................14 Parts List ............................14 Variations and Options .......................14 Warranty ............................14 PMC-6208...
  • Page 4: Unpacking

    S3125A PMC-6208...
  • Page 5: Features

    Features Features The PMC-6208 allows for manual control of all the functions of the PX-6216 without the requirement of a PC or Server. The PX-6216 is an 8-Bus Digital udio Matrixpart of the 6000digital P system. The PMC-6208 will control the main functions of PX-6216 such as...
  • Page 6: Front Panel

    Used to move the cursor, navigate and select the menu on the LCD screen. 6. ENTER BUTTON Used to select and accept the desired function. 7. ESC BUTTON Used to deselect the active menu and return to the previous menu. PMC-6208...
  • Page 7: Rear Panel

    1 2 3 4 5 6 7 8 1. MODE SWITCH (8 POSITION DIP SWITCH) The DIP switches are used for upgrading the PMC-6208 when new firmware and Software become available. 2. SERVICE PORT (4 POLE STEREO J CK), 3.5ø...
  • Page 8 PROGR M M NU L CONTROLLER PMC-6208 link cable Specification Standard TI /EI 568B standard terminated C T5 cable is used to connect the PMC-6208 to the DIB-6000 and PX-6216. [ TOP VIEW ] [ FRONT VIEW ] 8.Brown 7.W/Brown 6.Green...
  • Page 9: Operation

    PMC-6208 only. uto mode: Use this mode as a redundant/fail-safe operation mode. The primary mode of operation will by the PC and software. When both the controller/server PC and PMC-6208 are installed in tandem in a 6000 P...
  • Page 10 - Move the cursor to desired frequency band, and set the level using the Rotary Dial Switch. - To set other frequency band, press ESC Button and repeat the previous step. - When finished, press MENU or ESC button to return to the main menu. IN/OUT PUT SELECT INPUT CH OUTPUT CH PMC-6208...
  • Page 11 - From the main screen, press the arrow buttons to navigate and select <Ver>, and press ENTER key. - The devices connected to the PMC-6208 and their firmware versions will be displayed. - When finished, press MENU or ESC button to return to the main menu.
  • Page 12 1. The initial configuration of the PX-6216 is be done by PC using the MS-6800 configuration software during the system initial installation. 2. Update of the PX-6216 firmware to the most recent version is required in order to use PMC-6208 Manual Controller.
  • Page 13: Pplications

    It is possible to configure the PMC-6208 as fail-safe redundant controller. When both the controller/server PC and PMC-6208 are installed in tandem in a 6000 P system, the PMC-6208 will automatically take control of the P system when a PC failure is detected.
  • Page 14: Block Diagram

    PROGR M M NU L CONTROLLER Block Diagram Block Diagram PMC-6208...
  • Page 15: Specifications

    PROGR M M NU L CONTROLLER Specifications Specifications PMC-6208 Communication Standard RS-485 Operating Temperature -10°C ~ +40°C Power Source DC 24V Power Consumption Weight (SET) 4kg / 8.8lb Dimensions (SET) 482(W) x 88(H) x 280(D)mm/19(W)x 3.5(H) x 11(D) in * Design and specification are subject to be changed for the improvement of product quality without pre notice.
  • Page 16: Service

    To obtain specific warranty information and available service locations contact Inter-M directly or the authorized Inter-M Distributor for your specific country or region.
  • Page 17 NOTE...
  • Page 18 NOTE PMC-6208...
  • Page 19 PMC-6208...
  • Page 20 Inter-M, Ltd. (Korea) began operations in 1983. Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world. Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM).

Table of Contents