4.5.
Tab welding fig.4.
4.5.1.
disconnect equipment from power supply.
4.5.2.
insert tab welding tip into collet of machine and secure with collet lock nut.
4.5.3.
Insert tab into tab welding tip. Push fit is required.
4.5.4.
Adjust the ground pin such that the tip of the tab protrudes 4mm past the end of the ground pin (fig.4).
4.5.5.
Set power level as guided in section 4.3.
4.6.
Dent stick pulling adaptor. fig.5
4.7.
insert adaptor into welder collet and tighten collet nut to hold it.
4.7.1.
insert ground pin into base plate using screw knob to clamp it. the ground pin head should be 2 to 4mm behind the tip of
the adaptor.
4.7.2.
Set power level as guided in section 4.3.
nOte: The Dent Stick Adapter is designed to be used on small dents or finishing work only. It is not designed for large
damage repair. over welding and over pulling could result in damage to the welding tip, the panel or the welder.
fig.4
4.8. recommended voltage setting.
function
Al. stud Ø4.0
dent
stick
© Jack sealey limited
recommended voltage (V)
30 - 32
22 - 20
22 - 20
18 - 20
18 - 20
Original Language Version