Operating Specifications; Installation Instructions - Pentair LR-BB50 Installation And Operation Manual

Heavy duty
Hide thumbs Also See for LR-BB50:
Table of Contents

Advertisement

Available languages

Available languages

OPERATING SPECIFICATIONS

Flow Rate:
Pressure Range:
Temperature Range:
PRECAUTIONS
WARNING
Risk of electrical shock . If your water pipes are
used to ground your home' s electrical system, install a No . 8 AWG
jumper wire (or larger) around the filter. The jumper wire must
be connected at both ends by a pressure wire fitting or other
connection that satisfies NEC or CEC and local codes. Consult a
building inspector or licensed electrician for more information .
WARNING
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system .
WARNING
Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
CAUTION
Filter must be protected against freezing, which can
cause cracking of the filter and water leakage.
CAUTION
The rubber O-ring provides the water-tight seal
between the cap and the bottom of the housing . It is important
that the O-ring be properly seated in the groove above the
threads of the housing or a water leak could occur .
CAUTION
Because of the product' s limited service life and to
prevent costly repairs or possible water damage, we strongly
recommend that the bottom of all plastic housings be replaced
every five years for clear and every ten years for opaque. If the
bottom of your housing has been in use for longer than this
period, it should be replaced immediately . Date the bottom
of any new or replacement housing to indicate the next
recommended replacement date .
CAUTION
Do not use electrical heating tape on this unit .

INSTALLATION INSTRUCTIONS

NOTE:
• Please read all instructions, specifications, and precautions
before installing and using your water filter.
• There must be a shut-off valve before the filter.
• Install filter after water meter or pressure tank.
• Numbered diagrams correspond with numbered steps .
• Before installing the filter, determine where the unit will be
located and what type of pipe the unit will connect to . The
filter head has 1-inch NPT threaded connections molded into
it . Allow a 1-1/2 inch clearance below the housing to allow for
changing the cartridge .
• The recommended installation has a shut-off valve on both the
inlet and outlet sides of the filter. The installation shown uses
copper piping . The weight of the filter should be supported so
it does not stress the pipes . The main house water shut-off
valve can be used as the inlet side shut-off valve .
4
10 gpm
30-90 psi
40°–100°F
NOTES:
• For cold water use only .
• The contaminants or other substances removed
or reduced by this water treatment device are not
necessarily in your water . Ask your local water
municipality for a copy of their water analysis, or have
your water tested by a reputable water testing lab .
• Filter cartridge life varies depending on filter
type, usage, and water conditions .
• The replacement filter cartridge used with this system has a
limited service life. Changes in taste, odor, or flow of the water
being filtered indicate that the cartridge should be replaced.
• Use only Pentair
replacement cartridges .
§
• This installation must comply with all
applicable state and local regulations .
• Use only plumber tape without adhesive backing to
seal joints . Do not use pipe compound (pipe dope),
sticks, or similar compounds with this unit; they
contain petroleum derivatives which will cause crazing
and cracking of the plastic in the filter housing.
• Use only soap and water to clean filter
housing and components .
• After prolonged periods of non-use, such as a vacation, it
is recommended that the system be flushed thoroughly.
Let water run for 5–6 minutes before using .
• Do not use a torch near the unit .
• An activated carbon cartridge may contain a small amount
of carbon fines (very fine black powder). A new cartridge,
after installation, should be flushed with sufficient
water to remove the fines before using the water.
• Wear safety glasses during installation .
• Spent adsorption media will not be regenerated and used .
• If adsorption media is affected by chlorine,
influent will be treated to remove chlorine.
Suggested installation (10" Filter Housing shown)

Advertisement

Table of Contents
loading

Table of Contents