Pulse Response
Rise time (from 10 to 90%): ≤ 11μs
Fall time (from 90 to 10%): ≤ 11μs
AC noise on output: ≤ 1mV or 1A
Delay time at 10%: ≤ 10μs

3.2.3 Electrical Specifications, 10mV/A Sensitivity

Output impedance: 215Ω
MR417
Specified
Measurement range
Intrinsic uncertainty
MR527
Specified
Measurement range
Intrinsic uncertainty
Phase error (45 to 65Hz)
MR417
Specified Measurement range
Phase shift
MR527
Specified Measurement range
Phase shift
Current Probe Models MR417/MR527
peak-to-peak
0.5 to 30A
AC/DC
≤±(3% R + 5mV)
0.5 to 40A
AC/DC
≤±(3% R + 5mV)
1 to 20A
1 to 100A
30 to 40A
AC/DC
≤±1.5% R
40 to 100A
AC/DC
≤±1.5% R
AC
≤ -3°
AC
≤ -2°
40 to 60A
DC
≤±1.5% R
100 to 150A
DC
≤±1.5% R
20 to 40A
AC
≤ -2.2°