Clone Mode; Firmware Update; Programming Software Kpg-D6/D6N Description; Operation - Kenwood NX-1200 Series Service Manual

Uhf transceiver
Hide thumbs Also See for NX-1200 Series:
Table of Contents

Advertisement

2.2.3.4

Programming software KPG-D6/D6N description

The FPU is the programming software for the transceiver
supplied on a CD.
This software runs under Windows 7, 8.1, 10.
The data can be input to or read from the transceiver and edited
on the screen.

2.2.4 Clone mode

2.2.4.1
Outline
"Clone Mode" copies the transceiver data to another transceiver.
The dealer can copy the transceiver data to another transceiver
even without the use of a PC.
2.2.4.2
Example
The transceiver programming data can be copied from
transceiver to other transceivers through the cloning cable.
2.2.4.3

Operation

The following data cannot be cloned.
• ESN (Electronic Serial Number) data
• Model name
• Tuning data
• Backup data
• Embedded Message with Password
(1) In the source transceiver, press and hold the [Side 2]
button for two seconds while turning the transceiver power
ON and enter the Clone Mode.
The LED of transceiver lights in white.
(2) In the target transceiver, turning the transceiver power ON.
(3) Connecting the cloning cable (part No.E30-3410-05) to the
SP/MIC connectors on the source and target.
(4) Press the [PTT] button on the source while the white LED
of source lights.
The data of the source is sent to the target.
While the target is receiving the data, the green LED of the
target lights.
(5) When cloning of the data is completed, the LED of source
lights for 2 seconds in white and it turns off for 0.5 seconds
alternately. The target automatically operates in the User
mode.
The target can then be operated by the same program as
the source.
If data transmission failed while cloning, yellow and white
LED of target lights alternately.
If the cloning fails, no data will be available in the target
when it is returned to User mode.
(6) The other target can be continuously cloned.
When the [PTT] button on the source is pressed, the the
LED of source lights in white and a beep sounds.
Carry out the operation in step (2) to (5).
Note:
a) If the transceivers Clone Mode is configured as
disabled in the FPU optional features window, the
transceiver cannot enter Clone mode.
b) If the transceiver is in Error Mode, Clone mode
cannot be entered.
c) The conditions and operations when Clone becomes
impossible are as follows.
• The Password (Write) is set to the target
transceiver.
• Between transceivers where the data with different
Model Name, Frequency and Features.
• The Radio Feature setting is enabled on the source
side but the same Radio Feature License setting is
disabled on the target side.
• If the Disable Reading Key Data is enabled through
the FPU.
d) Source transceiver and Target transceiver must have
same model name data if they using the Clone
function.
e) Once transceiver is set to be the Source, it cannot be
a target after all data has been transmitted. This is to
protect the data in the Source transceiver.

2.2.5 Firmware Update

When updating the transceiver firmware, use the updater.
Connect the KPG-22U and execute the updater.
Cloning cable
(E30-3410-05)
Fig.2
(No.RA077<Rev.001>)1-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents