Document #9620-20-C-Jxx Valve Adapters with a Double Solenoid-02

4. Maintenance

Valve adapters should require little maintenance. The only wear components are the valve itself and an exhaust
muffler. Under normal operating conditions, the valve will last for millions of cycles. The exhaust muffler should be
check every 6 months of operation or more frequently in dirty environments to see if it is clogged.
WARNING: Do not perform maintenance or repair on Tool Changer or modules unless the
Tool is safely supported or placed in the tool stand, all energized circuits (e.g. electrical,
air, water, etc.) are turned off, pressurized connections purged and power discharged from
circuits in accordance with the customer's safety practices and policies. Injury or equipment
damage can occur with Tool not placed and energized circuits on. Place the Tool safely in the
tool stand, turn off and discharge all energized circuits, purge all pressurized connections,
verify all energized circuits are de-energized before performing maintenance or repair on Tool
Changer or modules.
To check if the exhaust muffler is clogged remove the muffler and blow through the muffler. If it is difficult to
blow or you cannot blow through it at all replace the exhaust muffler. Refer to
Replacement.