Manual, Valve adapters, Double Solenoid
Document #9620-20-C-Jxx Valve Adapters with a Double Solenoid-02
2. Installation
Valve adapters and tool adapter assemblies are typically installed by ATI prior to shipment. The steps below outline
the field installation or removal as required.
WARNING: Do not perform maintenance or repair on Tool Changer or modules unless the
Tool is safely supported or placed in the tool stand, all energized circuits (e.g. electrical,
air, water, etc.) are turned off, pressurized connections purged and power discharged from
circuits in accordance with the customer's safety practices and policies. Injury or equipment
damage can occur with Tool not placed and energized circuits on. Place the Tool safely in the
tool stand, turn off and discharge all energized circuits, purge all pressurized connections,
verify all energized circuits are de-energized before performing maintenance or repair on Tool
Changer or modules.
2.1 Valve Adapter Installation for QC-113, QC-210, QC-213, GL6L, GL7L
Tools required: 5 mm Allen wrench (hex key), 3 mm Allen wrench (hex key), torque wrench
Supplies required: clean rag
1. It may be necessary to clean the mounting surface on the Tool Changer or Utility Coupler prior to
installing the valve adapter in order to remove any debris that may be present.
2. (2) O-rings are required on the Master side Flat 'A' interface. Make sure these O-rings are present and
lightly lubricated (refer to
3. Using the ledge feature to place the valve adapter adjacent to the 'Flat A' mounting surface. Align the
valve adapter using the dowels in the bottom of the ledge feature. Apply Loctite 242 to the supplied M6
socket head cap screws. Secure the valve adapter using the M6 socket head cap screws and tighten to 70
in-lbs (7.9 Nm).
4. Apply Loctite 222 to the (2) supplied M5 socket flat head cap screws. Secure the valve adapter using the
fasteners, tighten the M5 socket flat head cap screws to 28 in-lbs (3.2 Nm).
5. Route the RTL (R1) sensor cable through the cable channel in the bottom of the valve adapter. Refer to
Figure 2.2.
(2) M6 Socket Head Cap Screws
Valve Adapter
9121-JE2-M (Shown)
(2) M5 Socket Flat
Head Cap Screws
(2) M6 Socket Head
Cap Screws
Control/Signal Module
Control/Signal Module Cleat
(3) M5 Socket Flat Head Cap Screws
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
Figure
2.1).
Figure 2.1—Valve Adapter Installation (QC-210 Shown)
Tool Changer Master
(QC-210 Shown)
(2) O-rings
Solenoid Cable
Cable Channel in Bottom of Valve Adapter Module
www.ati-ia.com
C-4
RTL (R1)
Sensor Cable
Pneumatic
Connection