Service Procedures; Exhaust Muffler Replacement - ATI Technologies 9121-JE2-M Manual

Valve adapters, double solenoid
Table of Contents

Advertisement

Manual, Valve adapters, Double Solenoid
Document #9620-20-C-Jxx Valve Adapters with a Double Solenoid-02

5.2 Service Procedures

The following service procedures provide instructions for inspection, adjustment, test or replacement of
components.
5.2.1 Exhaust Muffler Replacement
The exhaust muffler allows air from the Tool Changer or Utility Coupler locking mechanism to be
exhausted to the atmosphere, if the muffler is clogged it may affect the ability to Lock and Unlock
the Tool Changer. Remove and check to make sure the Exhaust muffler is not clogged.
Tools required: 11 mm Wrench
1. For Tool Changers, dock the Tool safely in the tool stand. Uncouple the Tool Changer or Utility
Coupler to allow clear access to the Master and Tool plates. Leave the locking mechanism in
the unlocked.
2. Turn off and de-energize all energized circuits (e.g. electrical, air, water, etc.).
3. Remove the exhaust muffler from the valve adapter, blow through the muffler, if it is difficult
to blow or you can not blow through it at all replace the exhaust muffler. Discard the exhaust
muffler.
4. Thread the new exhaust muffler into the valve adapter housing. Tighten to contact plus one turn.
Exhaust Muffler
5. After repair is complete, return all circuits to normal operation (e.g. electrical, air, water, etc.).
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
Figure 5.2— Exhaust Muffler Replacement