Valve Adapter Removal For Qc-310, Qc-313, Qc-510, Qc-1210; Tool Adapter Assembly Installation - ATI Technologies 9121-JE2-M Manual

Valve adapters, double solenoid
Table of Contents

Advertisement

Manual, Valve adapters, Double Solenoid
Document #9620-20-C-Jxx Valve Adapters with a Double Solenoid-02

2.4 Valve Adapter Removal for QC-310, QC-313, QC-510, QC-1210

NOTICE: Depending on maintenance or repair being performed, utilities to modules and Master
plate may need to be disconnected.
Tools required: 5 mm Allen wrench (hex key), 4 mm Allen wrench (hex key)
1. If the Tool Changer is already installed, dock the Tool side of the Tool Changer safely in the tool stand
and uncouple the Tool Changer to allow clear access to the Master and Tool plates of the Tool Changer.
2. Turn off and de-energize all energized circuits (e.g. electrical, air, water, etc.).
3. Disconnect the solenoid cable from the control/signal module and valve adapter.
4. Remove the control/signal module off the valve adapter. Refer to the control /signal module manual for
instructions.
5. Remove the (2) M5 socket head cap screws and the (2) M6 socket head cap screws and lift the valve
adapter off the Tool Changer. Refer to
6. Make sure that the O-rings are retained at the Master side Flat 'A' mounting interface.

2.5 Tool Adapter Assembly Installation

Tools required: 5 mm Allen wrench (hex key), 4 mm Allen wrench (hex key), torque wrench
Supplies required: clean rag
1. It may be necessary to clean the mounting surface on the Tool Changer or Utility Coupler prior to
installing the tool adapter assembly in order to remove any debris that may be present.
2. Using the ledge feature to place the tool adapter assembly adjacent to the 'A' mounting surface. Align
the tool adapter assembly using the dowels in the bottom of the ledge feature. Apply Loctite 242 to the
supplied M6 socket head cap screws. Secure the tool adapter assembly using the M6 socket head cap
screws and tighten to 89 in-lbs (10.0 Nm).
3. Apply Loctite 222 to the (2) supplied M5 socket head cap screws. Secure the tool adapter assembly
using the M5 socket head cap screws and tighten to 52 in-lbs (5.9 Nm).
(2) M6 Socket Head Cap Screws
(9005-20-1192) Tool Adapter Assembly
(2) M6 Socket Head
Cap Screws
Control/Signal
Tool Module
(2) M5 Socket Head Cap Screws
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
Figure 2.3.
Figure 2.4—Tool Adapter Assembly Installation
Tool Change Tool Plate
(QC-310 Shown)
C-7
• Email:
www.ati-ia.com
info@ati-ia.com