Valve Adapter Removal For Qc-113, Qc-210, Qc-213, Gl6L, Gl7L0 - ATI Technologies 9121-JE2-M Manual

Valve adapters, double solenoid
Table of Contents

Advertisement

Manual, Valve adapters, Double Solenoid
Document #9620-20-C-Jxx Valve Adapters with a Double Solenoid-02
6. Install the cleat from the control/signal module to retain the RTL (R1) sensor cable in the cable channel,
use the (3) M5 socket flat head cap screws to secure the cleat. Tighten to 14 in-lbs (1.6 Nm).
7. Make pneumatic connections to the valve adapter housing as required. Ensure that the connectors are
cleaned prior to being secured as appropriate. ATI recommends using a thread sealant such as Loctite
569 or similar.
8. Connect the solenoid cable to the connector on the valve adapter.
Valve Adapter
Cable Channel in Bottom
of Valve Adapter Module
Control/Signal Module Cleat

2.2 Valve Adapter Removal for QC-113, QC-210, QC-213, GL6L, GL7L0

NOTICE: Depending on maintenance or repair being performed, utilities to modules and Master
plate may need to be disconnected.
Tools required: 5 mm Allen wrench (hex key), 3 mm Allen wrench (hex key)
1. If the Tool Changer is already installed, dock the Tool side of the Tool Changer safely in the tool stand
and uncouple the Tool Changer to allow clear access to the Master and Tool plates of the Tool Changer.
2. Turn off and de-energize all energized circuits (e.g. electrical, air, water, etc.).
3. Disconnect the solenoid cable from the control/signal module and valve adapter.
4. Remove the control/signal module off the valve adapter. Refer to the control /signal module manual for
instructions.
5. Remove the (3) M5 socket flat head cap screws securing the control/signal module cleat, remove the
cleat. Refer to
6. Remove the RTL (R1) sensor cable from the cable channel in the bottom of the valve adapter. Refer to
Figure 2.2.
7. Remove the (2) M5 socket flat head cap screws and the (2) M6 socket head cap screws and lift the valve
adapter off the Tool Changer.
8. Make sure that the O-rings are retained at the Master side Flat 'A' mounting interface.
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
Figure 2.2—RTL (R1) Sensor Cable Routing
Figure 2.1.
Control/Signal Module
www.ati-ia.com
C-5
Tool Changer Master
(QC-210 Shown)
RTL (R1)
Sensor Cable
• Email:
info@ati-ia.com