Whelen Engineering Company CenCom Core C399 Installation Manual page 9

Main control box
Hide thumbs Also See for CenCom Core C399:
Table of Contents

Advertisement

CONNECTOR - PIN - FUNCTION
J15 -
1 BLU - RADIO IN (+)
-
J15 -
2 - GRN - AUX IN (+)
J15 -
3 - YEL - CAB SPKR (+)
J15 -
4 - WHT/VIO- AUX OUT (+)
J15 -
5 - BLU - RADIO IN (-)
J15 -
6 - GRN - AUX IN (-)
J15 -
7 - WHT/YEL - CAB SPKR (-)
J15 -
8 - VIO - AUX OUT (-)
J17
- 1 - ORG - OUTPUT 19
J17 -
2 - RED - OUTPUT 18
J17 -
3 - YEL - OUTPUT 20
J17 -
4 - BRN - OUTPUT 17
J17 -
5 - GRN - OUTPUT 21
J17 -
6 - BLU - OUTPUT 22
J14
- 1 - WHT/BLK - Analog 1 (+)
J14 -
2 - WHT/GRY - Analog 2 (+)
J14 -
3 - RED/WHT - Ignition (+)
J14 -
4 - WHT/VIO - Analog 3 (+)
J14 -
5 - WHT/BLU - Analog 4 (+)
J14 -
6 - WHT/GRN - N/C
J6
- 1 - WHT/BRN - INPUT 1
J14 -
2 - WHT/RED - INPUT 2
J14 -
3 - WHT/ORG - INPUT 3
J14 -
4 - WHT/YEL - INPUT 4
J14 -
5 - WHT/GRN - INPUT 5
J14 -
6 - WHT/BLU / INPUT 6
J14 -
7 - WHT/VIO - INPUT 7
J14 -
8 - WHY/GRY - INPUT 8
J14 -
9 - WHT/BLK - INPUT 9
J14 -
10 - BRN - INPUT 10
J14 -
11 - RED - INPUT 11
J14 -
12 - ORG - INPUT 12
J10
- 1 - BRN - OUTPUT 1
J10 -
2 - RED - OUTPUT 2
J10 -
3 - ORG - OUTPUT 3
J10 -
4 - YEL - OUTPUT 4
J10 -
5 - GRN - OUTPUT 5
J10 -
6 - BLU - OUTPUT 6
J10 -
7 - VIO - OUTPUT 7
J10 -
8 - GRY - OUTPUT 8
J10 -
9 - WHT/BRN - OUTPUT 9
J10 -
10 - WHT/RED - OUTPUT 10
J10 -
11 - WHT/ORG - OUTPUT 11
J10 -
12 - WHT/YEL - OUTPUT 12
J10 -
13 - WHT/GRN - OUTPUT 13
J10 -
14 - WHT/BLU - OUTPUT 14
J10 -
15 - WHT/VIO - OUTPUT 15
J10 -
16 - WHT/GRY - OUTPUT 16
ASSIGNED TO:
(Pre-Assigned: Backlighting)
(Pre-Assigned: Horn Ring)
(Pre-Assigned: : Park Kill)
Page 9
Cencom™ Core™
Installation Worksheet
This worksheet has been provided
so that a written record of all Input,
Output and Axillary connections may
be created. After all data has been
verified and recorded, store and
retain this sheet for future reference.
It is recommended that you make a
copy of this worksheet before filling in.
so that if any changes need to be
made you will have a blank copy.
WARNING!All customer supplied wires
that connect to the positive terminal of
the battery must be sized to supply at
least 125% of the maximum operating
current and fused "at the battery" to
carry that load
DIGITAL INPUTS