Ready Dvptc Airflow Tables - Daikin ComfortNet DX16TC Series Service Instructions Manual

Condensing units, split system heat pumps with r-410a refrigerant blowers, coils, & accessories
Hide thumbs Also See for ComfortNet DX16TC Series:
Table of Contents

Advertisement

SERVICING

READY DVPTC AIRFLOW TABLES

Speed Selection Dip Switches
Cool
Adjust
Selection
Selection
Switches
Switches
TAP
S1
S2
S3
A
OFF
OFF
OFF
B
ON
OFF
ON
C
OFF
ON
OFF
D
ON
ON
ON
Profiles
Pre-Run
A
------
B
------
C
------
D
------
To set Airflow: (1) Select model and desired High Stage Cooling
Airflow. Determine the corresponding tap (A, B, C, D). Set dip
switches S1 and S2 to the appropriate ON / OFF positions.
(2) Select model and installed electric heater size. Set dip
switches S9, S10, and S11 to the appropriate ON / OFF
positions.
(3) If airflow adjustment is required set Trim Enable Switch S8
to ON (OFF = 0% Trim) and set S3 and S4 to appropriate ON /
OFF positions. Tap A is +5% ,Tap B is -5%, Tap C is +10%, Tap D
is -10%.
To Set Comfort mode: Select desired Comfort Mode Profile
(see profiles above). Set dip switches S5 and S6 to appropriate
ON /OFF positions.
Dehumidification: To enable, set dip switch S7 to ON. Cooling
airflow will be reduced to 85% of nominal value during cool
call when Dehum command is present. To disable, set S7 to
OFF.
Continuous Fan Speed: Use dip switches S12 and S13 to select
one of 4 continuous fan speeds, Tap A is 25%. Tap B is 50%, Tap
C is 75%, Tap D is 100%.
Notes:
1. Airflow data shown applies to legacy mode operation only.
For a fully communicating system, please see the outdoor
unit's installation instructions for cooling and heat pump
airflow data. See ComfortNet System-Airflow Consideration
section for details.
2. Airflow blink codes are approximations of actual airflow.
Profile
Continuous
Selection
Fan Speed
Switches
S4
S5
S6
S12
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
Short-Run
OFF Delay
------
60 sec/100%
30 sec/50%
60 sec/100%
7.5 min/82%
60 sec/100%
7.5 min/82%
30 sec/50%
Cooling/Heat Pump Airflow Table
MODEL
DV25PTCB14
S13
DV29PTCB14
ON
DV37PTCB14
ON
DV31PTCC14
DV37PTCC14
DV33PTCC14
DV39PTCC14
DV49PTCC14
DV59PTCC14
DV37PTCD14
DV59PTCD14
DV49PTCD14
DV61PTCD14
77
Tap
Low Stage
High Stage
A
410
B
565
C
650
D
685
A
375
B
545
C
630
D
740
A
590
B
705
C
845
D
910
A
475
B
565
C
690
D
760
A
665
B
770
C
815
D
910
A
710
B
745
C
880
D
975
A
610
B
810
C
940
D
1070
A
605
B
725
C
820
D
940
A
1040
B
1260
C
1330
D
1395
A
820
B
895
C
995
D
1056
A
1080
B
1210
C
1280
D
1350
610
840
970
1020
610
795
930
1085
880
1055
1265
1360
690
785
980
1110
990
1150
1095
1225
955
1005
1180
1310
875
1225
1410
1595
900
1080
1225
1405
1445
1790
1890
1990
1195
1320
1460
1530
1630
1820
1925
2025