Daikin ComfortNet DX16TC Series Service Instructions Manual page 22

Condensing units, split system heat pumps with r-410a refrigerant blowers, coils, & accessories
Hide thumbs Also See for ComfortNet DX16TC Series:
Table of Contents

Advertisement

ACCESSORIES
DV**PTC14**
Heat Kit Applications
Type / Model
HKSX03XC
HKSX05XC
HKSX06XC
HKSX08XC
HKSX10XC
HKSX15XF*
HKSX20XF*
HKSC05XC
HKSC08XC
HKSC10XC
HKSC15XA
HKSC15XB
HKSC15XF*
HKSC19CA*
HKSC19CB*
HKSC20DA
HKSC20DB
HKSCX20XF*
HKSC25DC*
* Revision level that may or may not be designated.
Refer to the minimum airflow requirements for each of the heat kits.
†For ma tch up wi th a 2 ton outdoor uni t: Hea ter ki t a ppl i ca ti on s ha l l not exceed 10 kW.
Ai rfl ow for 5 kW up to 10 kW hea ter ki ts s ha l l be s et to 850 cfm s peed ta p of ON-ON-ON.
††For ma tch up wi th a 3 ton outdoor uni t: Hea ter ki t a ppl i ca ti on s ha l l not exceed 15 kW.
Ai rfl ow for 5 kW up to 15 kW hea ter ki ts s ha l l be s et to 1400 cfm s peed ta p of ON-ON-OFF.
†††For ma tch up wi th a 3.5 ton outdoor uni t: Hea ter ki t a ppl i ca ti on s ha l l not exceed 20 kW.
Ai rfl ow for 5 kW up to 20 kW hea ter ki ts s ha l l be s et to 1620 cfm s peed ta p of ON-ON-OFF
** 3 kW hea ter ki t i s not a ppl i ca bl e for thi s i ndoor a ppl i ca ti on.
DV**PTC
24B
30C
36C
48C
42D
††
48D
†††
60D
Note: Ai rfl ow da ta s hown a ppl i es to the el ectri c hea t onl y i n ei ther l ega cy mode or communi ca ti ng mode opera ti on
†For ma tch up wi th a 2 ton outdoor uni t: Hea ter ki t a ppl i ca ti on s ha l l not exceed 10 kW.
Ai rfl ow for 5 kW up to 10 kW hea ter ki ts s ha l l be s et to 850 cfm s peed ta p of ON-ON-ON.
††For ma tch up wi th a 3 ton outdoor uni t: Hea ter ki t a ppl i ca ti on s ha l l not exceed 15 kW.
Ai rfl ow for 5 kW up to 15 kW hea ter ki ts s ha l l be s et to 1300 cfm s peed ta p of ON-OFF-ON.
†††For ma tch up wi th a 3.5 ton outdoor uni t: Hea ter ki t a ppl i ca ti on s ha l l not exceed 20 kW.
Ai rfl ow for 5 kW up to 20 kW hea ter ki ts s ha l l be s et to 1500 cfm s peed ta p of ON-OFF-OFF
** 3 kW hea ter ki t i s not a ppl i ca bl e for thi s i ndoor a ppl i ca ti on.
24B14-A*
30C14-A*
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
3
5
6
550
650
700
600
700
750
850
900
850
900
850**
1250
1300
1250
1300
1250
1300
Mi ni mum CFM requi red for Hea ter Ki ts
DVPTC
36C14-A*
48C14-A*
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
HEATER (kW)
8
10
15
800
850
875
950
1000
1200
1440
1000
1200
1440
1500
1550
1720
1500
1550
1720
1500
1550
1780
22
††
42D14-A*
48D14-A*
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
19
20
21 or 25
1500
1500
1800
1815
1850
1850
1850
†††
60D14-A*
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X