Mbvc Airflow Table - Daikin ComfortNet DX16TC Series Service Instructions Manual

Condensing units, split system heat pumps with r-410a refrigerant blowers, coils, & accessories
Hide thumbs Also See for ComfortNet DX16TC Series:
Table of Contents

Advertisement

SERVICING
Speed Selection Dip Switches
Cool
Adjust
Selection
Selection
Switches
Switches
TAP
1
2
3
A
OFF
OFF OFF OFF
B
ON
OFF
ON
C
OFF
ON OFF
D
ON
ON
ON
Profiles
Pre-Run
A
-------
B
-------
C
-------
D
30 sec/50%
To set airflow:
(1) Select model and desired
high stage cooling airflow. Determine the cooresponding tap
( A, B, C, or D ). Set dip switches 1 and 2 to the appropriate
ON / OFF positions. (2) Select model and installed electric
heater size. Set switches 9, 10, and 11 to the appropriate
ON/OFF positions. (3) Select the airflow adjustment factor tap
A and D are 0%; Tap B is +10%; Tap C - 10%. Set dip switches 3
and 4 to the appropriate ON / OFF positions.
Select desired Comfort Mode profile
To set Comfort Mode:
(see profiles above). Set switches 5 and 6 to the approriate
ON / OFF positions.

MBVC Airflow Table

Profile
Selection
Switches
4
5
6
OFF OFF
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
Short-Run
OFF Delay
--------
60 sec/100%
30 sec/50%
60 sec/100%
7.5 min/82%
60 sec/100%
7.5 min/82%
30 sec/50%
0140A00045
Htr Kw
9
1 0
11
MBVC1200*
3
ON
ON
ON
5
ON
ON
OFF
6
ON
OFF
ON
8
ON
OFF
OFF
10
OFF
ON
ON
15
OFF
ON
OFF
20
OFF
OFF
ON
Model
Tap
A
*
B
MBVC1200
C
D
A
*
B
MBVC1600
C
D
A
*
B
MBVC2000
C
D
74
MBVC1 6000*
MBVC2000*
600
800
600
800
635
800
740
1000
1000
1000
1400
1500
NR
NR
Low Stage
High Stage
Cool
Cool
400
600
540
800
670
1000
800
1200
670
1000
800
1200
940
1400
1070
1600
800
1200
1070
1600
1200
1800
1340
2000
800
800
800
1000
1200
1500
2000