Daikin ComfortNet DX16TC Series Service Instructions Manual page 64

Condensing units, split system heat pumps with r-410a refrigerant blowers, coils, & accessories
Hide thumbs Also See for ComfortNet DX16TC Series:
Table of Contents

Advertisement

SERVICING
Air conditioner/heat pump
fails to operate.
Integrated control module
diagnostic/status LED
display shows the indicated
code.
displays error message.
Air conditioner/heat pump
fails to operate.
Integrated control
module diagnostic/status
LED display shows the
indicated code.
displays error message.
Very long run time.
Four consecutive
compressor protector
trips with average run
time between trips greater
than 3 hours.
Compressor operating at
high speed and outdoor fan
operating at low speed
Integrated control
module diagnostic/status
LED display shows the
indicated code.
Compressor and outdoor
fan are off.
Thermostat demand is
present.
Integrated control
module diagnostic/status
LED display shows the
indicated code.
d
3
Mis-match
d
4
Invalid
Memory
Card Data
0
1
Low Side
LOW SIDE
Fault
0
1
Low Pressure
Cut Out Trip
d3
Shared data sent
to integrated
control module
does not match
hardware
d4
Shared data on
MC DATA
memory card has
been rejected.
01
Low refrigerant
FAULT
charge.
Restriction in
liquid line.
Indoor blower
motor failure.
Indoor
thermostat set
extremely low.
01
Low refrigerant
charge.
Restriction in
liquid line.
Indoor blower
motor failure.
Indoor
thermostat set
extremely low.
64
Verify
Turn power OFF prior
system type
to repair.
(communicating
Use memory card for
or legacy).
Verify shared
Insert memory card
data is correct
BEFORE turning power
model; re-
be removed after data
populate data if
is loaded. Turn power
required.
OFF before removing
Wire system as
memory card.
legacy system.
Error code will
be cleared once
data is loaded.
Applies only to fully
communicating system
thermostat.
Verify
Turn power OFF prior
system type
to repair.
(communicating
Use memory card for
or legacy).
Verify shared
Insert memory card
data is correct
BEFORE turning power
model; re-
be removed after data
populate data if
is loaded. Turn power
required.
OFF before removing
Wire system as
memory card.
legacy system.
Error code will be
cleared once data is
loaded.
Verify refrigerant
Turn power OFF prior
charge; adjust as
to repair.
needed.
Fault will clear after 30
Check for
consecutive normal
restricted liquid
cycles.
line; repair/
Fault may be cleared
replace as
by cycling 24VAC to
needed.
control.
Check indoor
Replace with correct
blower motor;
replacement part(s).
repair/replace as
needed.
Check indoor
thermostat setting.
Verify refrigerant
Turn power OFF prior
charge; adjust as
to repair.
needed.
Replace with correct
Check for
replacement part(s).
restricted liquid
line; repair/
replace as
needed.
Check indoor
blower motor;
repair/replace as
needed.
Check low
pressure switch;
repair/replace as
needed.
Check indoor
thermostat setting.