Users Manual
default frm address is the first point on the waveform or the point most recently edited
if point edit has been used. Set the from address and value by pressing the
appropriate soft key and making an entry direct from the keyboard or by using the rotary
control; repeat for the to address and value.
The line will be drawn between the two selected points when the draw line soft key
is pressed.

Wave Insert

Pressing wave insert... calls the wave insert screen:
Wave insert places waveforms between programmable start and stop points. Both
standard and arbitrary waveforms can be inserted in the new waveform, with the
exception of pulse, pulse-train and sequence.
A section of an arbitrary waveform can be inserted, as defined by the left hand strt
(start) and stop addresses (0 and 512 of WFM1 on the screen above); these addresses
default to the start and stop of the whole waveform but can be reset to define any section
of the waveform. Change the addresses by pressing the appropriate soft key and making
entries from the keyboard or using the rotary control. The destination of the selected
section of the source waveform in the new waveform is defined by the right hand strt
(start) and stop addresses. Change the addresses by pressing the appropriate soft key and
making entries from the keyboard or using the rotary control.
The insertion is confirmed by pressing the insert soft key. If there is a size
difference between the two sections of waveform then the software will expand or
compress the source to fit the new waveform. Compressing the waveform can cause
some significant data to be lost.
To insert sections of the current waveform into itself, see Block Copy

Block Copy

Pressing block copy... calls the BLOCK COPY screen:
Block copy allows a section of the current waveform to be inserted within itself. The
block to be inserted is defined by the start and stop addresses. Change the
addresses by pressing the appropriate soft key and making entries from the keyboard or
using the rotary control.
The destination address for the start of the section is set by pressing the dest soft key
and entering the address.
9-8
Shop for Fluke products online at:
WFM1
WFM2
000000 strt0000400
000512 stop0100000
exit
insert
BLOCK COPY: WFM42
start:0000400
stop: 0001000 copy
dest: 0000000 exit