Bloomfield 1222 1222CA Owner's Manual

Hot water dispenser

Advertisement

WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
telephone: 775-689-5707
www.wellsbloomfield.com
Model 1222 Dispenser
76580
p/n
Rev. G ECN-13387
fax: 775-689-5976
PRINTED IN UNITED STATES OF AMERICA
OWNERS MANUAL
for
HOT WATER
DISPENSER
2 GALLON MODELS:
1222
1222CA
5 GALLON MODELS:
1225
1226
Includes:
Installation
Operation
Use & Care
Servicing Instructions
M712
712
07
1120 cps

Advertisement

Table of Contents
loading

Summary of Contents for Bloomfield 1222 1222CA

  • Page 1 WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 775-689-5707 fax: 775-689-5976 www.wellsbloomfield.com Model 1222 Dispenser 76580 Rev. G ECN-13387 PRINTED IN UNITED STATES OF AMERICA OWNERS MANUAL HOT WATER DISPENSER 2 GALLON MODELS: 1222...
  • Page 2: Warranty Statement

    Be sure to retain the container for inspection. Be certain that any Wells Bloomfield cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
  • Page 3: Table Of Contents

    1222 1222CA 1225 1226 Meets Canadian standards This manual applies to the following Wells Bloomfield products: 1222 2-Gallon Hot Water Dispenser 1222CA 2-Gallon Hot Water Dispenser 1225 5-Gallon Hot Water Dispenser 1226 5-Gallon Hot Water Dispenser Thank You for purchasing this Wells Bloomfield appliance.
  • Page 4: Features & Operating Controls

    FEATURES AND OPERATING CONTROLS...
  • Page 5: Precautions & General Information

    WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: INJURY HAZARD All installation procedures must be performed by qualified personnel with full knowledge of all...
  • Page 6: Installation Instructions

    INSTALLATION READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: To enable the installer to make a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started: CAUTION: EQUIPMENT DAMAGE DO NOT plug in or energize this appliance until all Installation Instructions are read and...
  • Page 7 NSF requires that the unit be able to be moved for cleaning underneath. A flex line or loops of copper tubing will satisfy this requirement. See Figure 2 below. In some areas, local codes require a backflow preventer (check valve) to be installed on the inlet water line. If a backflow preventer is used, you must install a water hammer arrester in the incoming line, between the backflow preventer and the brewer inlet, as far away from the brewer as space will allow.
  • Page 8: Operation

    OPERATION Fig. 3 Dispenser Operation Diagram IMPORTANT: A. START-UP Be sure tank is filled with water before pressing tank heater switch to ON. IMPORTANT: Fill the water tank before energizing tank heater: B. USE 1. Always use a container suitable for hot water. WATER HEATER Water temperature is sensed by thermobulb inserted into the water tank.
  • Page 9: Cleaning Instructions

    PROCEDURE: Clean Hot Water Dispenser PRECAUTIONS: Disconnect dispenser from electric power. Allow dispenser to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush 1. Disconnect dispenser from electric power. Allow to cool before cleaning. 2. Wipe exterior of dispenser with a soft clean cloth or sponge moistened with mild detergent and clean water.
  • Page 10: Troubleshooting Suggestions

    TROUBLESHOOTING SUGGESTIONS SYMPTOM Water won’t heat No flow from hot water faucet Water faucet drips POSSIBLE CAUSE Dispenser unplugged or circuit breaker tripped Tank heater switch "OFF" Temperature setpoint too low Hi-Limit safety switch tripped Damaged internal component or wiring Water supply OFF Solenoid inlet strainer plugged Water filter (if used) plugged...
  • Page 11: Servicing Instructions

    ACCESS PANELS REAR PANEL: Remove rear panel to access hot water tank, thermostat, heating elements, tubing, water level control and plumbing connections. Rear panel is held by four screws at the back. The flanged top portion fits over the body of the dispenser. SOLENOID DOOR: Solenoid door may be removed to aid in solenoid replacement.
  • Page 12 SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Check temperature at discharge of faucet. Remove thermostat access button plug to access thermostat. Turn thermostat shaft clockwise to increase temperature. REMOVE TANK LID ASSEMBLY Unplug dispenser or turn circuit breaker OFF. Turn OFF water supply.
  • Page 13 REPLACE HEATING ELEMENT Remove tank lid assembly as detailed on page 10. Remove two hex nuts holding element to cover. Pull element from mounting holes. Reassemble in reverse order. REPLACE SOLENOID Unplug power cord. Turn OFF and disconnect water supply from dispenser inlet fitting.
  • Page 14: Deliming Instructions

    SERVICING INSTRUCTIONS (continued) CAUTION: CHEMICAL BURN HAZARD Deliming chemicals may be caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and experienced service personnel. IMPORTANT: DO NOT spill, splash or pour water or deliming solution into or over any internal...
  • Page 15 SERVICE KITS FAUCET REPAIR KITS 84686 Faucet & Shank Complete 8700-25 L Seat Cup (only) SOLENOID REPAIR KITS 83612 Solenoid Complete, Single 120V (1222, 1222CA) 83760 Solenoid Complete, Single 240V (1225, 1226) 85218 Inlet Fitting Kit (includes cap, fitting, washer & screen) 85219 Inlet Strainer (only) EXPLODED VIEWS AND PARTS LISTS...
  • Page 16: Exploded View & Parts List

    EXPLODED VIEW & PARTS LIST 2 REQD 2 REQD NOTE: Model 1225/1226 shown. Model 1222/1222CA is similar.
  • Page 17 ITEM DESCRIPTION WRAP, BODY TANK ASSY PANEL, TOP BACK PLUG, BUTTON 7/8" SUPPORT, TANK LIGHT, PILOT GREEN LABEL, HW DISPENSER LIGHT, PILOT AMBER CONTROL, LOW WATER, 120V CONTROL, LOW WATER, 240V SPACER, NYLON PANEL, REAR LOWER SOLENOID, SINGLE 120V SOLENOID SINGLE 240V DOOR, ACCESS SWITCH, ROCKER 250V STRAIN RELIEF...
  • Page 18: Wiring Diagrams

    WIRING DIAGRAM 2-GALLON MODELS 1222 and 1222CA HOT WATER READY LIGHT (AMBER) THERMOSTAT BLACK WHITE GREEN WATER LEVEL WATER CONTROL LEVEL BOARD PROBE 120V POWER CORD NEMA 5-15P BLACK WHITE MODEL 1222 and 1222CA POWER LIGHT (GREEN) BLACK BLACK TANK HEATER SWITCH GREEN...
  • Page 19 5-GALLON MODELS 1225 and 1226 THERMOSTAT WHITE COMM WATER LEVEL CONTROL N.O. BOARD WATER N.C. LEVEL PROBE INPUT COMM GREEN 240V POWER CORD NEMA 6-30P BLACK WHITE MODEL 1225 and 1226 WIRING DIAGRAM (continued) HOT WATER READY LIGHT (AMBER) BLACK BLACK MODULE BLACK...
  • Page 20 Commercial Food Equipment Service Association Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association SERVICE TRAINING - QUALITY SERVICE SERVICE TRAINING - QUALITY SERVICE Genuine Parts Protect - YOU - All - Ways CUSTOMER SATISFACTION CUSTOMER SATISFACTION WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P.

This manual is also suitable for:

12221222ca12251226

Table of Contents