Bloomfield 1222CA Owner's Manual

2- & 5-gallon hot water dispenser
Hide thumbs Also See for 1222CA:

Advertisement

Quick Links

10 Sunnen Drive
St. Louis, MO 63143
telephone: 314-678-6336
fax: 314-781-2714
www.wellsbloomfield.com
Model 1222 Dispenser
76580
2M-
Rev. I
OWNERS MANUAL
for
HOT WATER
DISPENSER
2 GALLON MODELS:
1222
1222CA
5 GALLON MODELS:
1225
1226
Includes:
Installation
Operation
Use & Care
Servicing Instructions
11
M712
0215
712

Advertisement

Table of Contents
loading

Summary of Contents for Bloomfield 1222CA

  • Page 1 10 Sunnen Drive St. Louis, MO 63143 telephone: 314-678-6336 fax: 314-781-2714 www.wellsbloomfield.com OWNERS MANUAL HOT WATER DISPENSER 2 GALLON MODELS: 1222 1222CA 5 GALLON MODELS: 1225 1226 Includes: Installation Operation Use & Care Servicing Instructions Model 1222 Dispenser 76580 Rev. I...
  • Page 2: Warranty Statement

    The prices charged by Bloomfield Industries for its products original installation or eighteen (18) months from the date of are based upon the limitations in this warranty. Seller’s...
  • Page 3: Table Of Contents

    4000 1225 NEMA 6-30P 4000 16.5 1226 Meets Canadian standards APPLICABILITY This manual applies to the following Wells Bloomfield products: 1222 2-Gallon Hot Water Dispenser 1222CA 2-Gallon Hot Water Dispenser 1225 5-Gallon Hot Water Dispenser 1226 5-Gallon Hot Water Dispenser...
  • Page 4: Features & Operating Controls

    FEATURES AND OPERATING CONTROLS REAR COVER REAR VIEW FRONT VIEW THERMOSTAT ACCESS READY LITE POWER LITE FLEXIBLE DRAIN LINE WATER SUPPLY CONNECTION TANK HEATER SWITCH DISPENSE FAUCET DRAIN LINE TUBING CLAMP POWER CORD RUBBER IL2081 GRIP FEET...
  • Page 5: Precautions & General Information

    PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: INJURY HAZARD All installation procedures must be performed by qualified personnel with full knowledge of all...
  • Page 6 1/4-turn ball valve, to avoid loss of water flow thru the criteria to insure successful valve. operation of the dispenser. Bloomfield recommends 1/4” copper tubing for installation of less than 12 feet and 3/8” for more than 12 feet from a 1/2”...
  • Page 7: Installation Instructions

    NEMA 5-15R). the event of internal damage. Model 1222CA is equipped with a cord and plug. It requires a Never cut off the ground prong 115 - 125 volt 15 amp circuit (50/60 Hz, 2 wire plus ground, with nor twist a blade to fit an NEMA 5-15R).
  • Page 8: Operation

    OPERATION WATER HEATER Water temperature is sensed by thermobulb inserted into the water tank. Temperature is controlled by a mechanical thermostat. The setpoint temperature is adjustable by turning the thermostat shaft. Excessive temperature will trip the hi-limit safety switch, disabling the heating element. The hi-limit will automatically reset when the dispenser cools.
  • Page 9: Cleaning Instructions

    CLEANING INSTRUCTIONS CAUTION: PROCEDURE: Clean Hot Water Dispenser BURN HAZARD PRECAUTIONS: Disconnect dispenser from electric power. Allow dispenser to cool. Dispensed water is extremely hot. Hot water will cause Daily FREQUENCY: serious skin burns. Mild Detergent, Clean Soft Cloth or Sponge TOOLS: Bristle Brush CAUTION:...
  • Page 10: Troubleshooting Suggestions

    TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Check power supply cord Dispenser unplugged or circuit breaker tripped Check / reset circuit breaker Tank heater switch “OFF” Press switch to “ON” Temperature setpoint too low Adjust thermostat for desired temperature Water won’t heat Hi-Limit safety switch tripped Allow to cool hi-limit will self-reset Examine wiring &...
  • Page 11: Servicing Instructions

    SERVICING INSTRUCTIONS ACCESS PANELS CAUTION: SHOCK HAZARD REAR PANEL: Remove rear panel to access hot water tank, thermostat, Opening access panels on heating elements, tubing, water level control and plumbing this dispenser may expose connections. uninsulated electrical Rear panel is held by four screws at the back. The flanged top components.
  • Page 12 SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT IMPORTANT: The thermostat will maintain Check temperature at discharge of faucet. temperature within ±3ºF. Remove thermostat access button plug to access thermostat. For high altitude locations, Turn thermostat shaft clockwise to increase temperature. thermostat should be adjusted to a maximum temperature equal to the local boiling temperature minus 5º.
  • Page 13 SERVICING INSTRUCTIONS (continued) IMPORTANT: REPLACE HEATING ELEMENT When replacing heating Remove tank lid assembly as detailed on page 10. element, also replace seal Remove two hex nuts holding element to cover. Pull element gaskets. from mounting holes. Reassemble in reverse order. REPLACE SOLENOID Unplug power cord.
  • Page 14 Should deliming hoses up. Rinse with clean water. become necessary, Bloomfield recommends replacing the Reassemble the tank lid to the water tank. Make sure the hoses gasket is properly in place.
  • Page 15 FITTING SHANK ASSY FAUCET (Tank Fitting) IL2080 BODY SERVICE KITS FAUCET REPAIR KITS WS-86597 Faucet & Shank Complete (1222, 1222CA) 2U-71460 Seat Cup (only) 2U-84396 Shank Assy, Faucet 2U-87030 Faucet Assy Brass (1225, 1226) SOLENOID REPAIR KITS 2E-73612 Solenoid Complete, Single 120V (1222, 1222CA)
  • Page 16: Exploded View & Parts List

    EXPLODED VIEW & PARTS LIST 2 REQD 2 REQD HOT WATER DISPENSER IL2065a NOTE: Model 1225/1226 shown. Model 1222/1222CA is similar.
  • Page 17 EXPLODED VIEW & PARTS LIST (continued) ITEM DESCRIPTION 1222 P/N 1222CA P/N 1225 P/N 1226 P/N WRAP, BODY C7-76579 C7-76709 TANK ASSY C7-76578 C7-76710 PANEL, TOP BACK C7-76512 C7-76713 PLUG, BUTTON 7/8” 2P-70714 SUPPORT, TANK C7-76521 C7-76712 LABEL, HW DISPENSER...
  • Page 18: Wiring Diagrams

    WIRING DIAGRAM 2-GALLON MODELS 1222 and 1222CA...
  • Page 19 WIRING DIAGRAM (continued) 5-GALLON MODELS 1225 and 1226 HOT WATER READY LIGHT (AMBER) POWER BLACK BLACK LIGHT (GREEN) THERMOSTAT BLACK BLACK HEATING ELEMENT 4000 WATTS WHITE COMM WATER LEVEL CONTROL N.O. BOARD TANK WATER HEATER N.C. LEVEL SWITCH PROBE HI-LIMIT BLACK RED12ga.
  • Page 20 10 Sunnen Drive, St. Louis, MO 63143 telephone: 314-678-6336 fax: 314-781-2714 www.wellsbloomfield.com...