Download Print this page
ACP RMS510TS2 Technical Information

ACP RMS510TS2 Technical Information

Commercial microwave 230v, 50 hz

Advertisement

Quick Links

Commercial Microwave
230V, 50 Hz Models
RMS510TS2
RMS510TSUA
RMS510TSCA
RMS510TSAA
Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit.
Refer to Owner's Manual for installation and operating instructions
To avoid the risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Model
RMS510TS2
EMEA, SEA, LATAM
RMS510DS2
EMEA, SEA, LATAM
RMS510TSUA
EMEA, UK, LATAM
RMS510DSUA
EMEA, UK, LATAM
RMS510TSAA
RMS510TSCA
RMS510TSIA
Power Output
Nominal microwave energy (IEC705)
Minimum temperature rise (∆T)
Operating Frequency
Dimensions
Cabinet
Oven Interior
Weight
July 2019
©2019 ACP, Inc.
P2006703M
P2006707M
P2006709M
P2006711M
Region
Control
Touch
Dial
Touch
Dial
Australia
Touch
China
Touch
India
Touch
Models
Width
Height
Depth
Width
Height
Depth
Crated
Uncrated
Technical Information
RMS510DS2
RMS510DSUA P2006708M
RMS510TSIA
Consumption
Power Source
1500 W, 7.3 A
230v, 50hz, 16A
1500 W, 7.3 A
230v, 50hz, 16A
1500 W, 7.3 A
230v, 50hz, 13A
1500 W, 7.3 A
230v, 50hz, 13A
1500 W, 7.3 A
230v, 50hz, 10A
1500 W, 7.3 A
230v, 50hz, 16A
1500 W, 7.3 A
230v, 50hz, 16A
RMS510D / RMS510T*
1000 Watts
10º F / 5º C
2450 MHz
311mm
419mm
330.2mm (13")
197mm (7 3/4")
330.2mm (13")
14.5 kg. (39 lbs.)
17.7 kg. (32 lbs.)
1
P2006704M
P2006710M
Plug Type
CEE 7/7 "Schuko"
CEE 7/7 "Schuko"
BS1363/A
BS1363/A
Type 1
BS546
508mm (20")
(12 1/4")
(16 1/2")
China
16500066

Advertisement

loading

Summary of Contents for ACP RMS510TS2

  • Page 1 Width 508mm (20") Height 311mm (12 1/4") Depth 419mm (16 1/2") Oven Interior Width 330.2mm (13") Height 197mm (7 3/4") Depth 330.2mm (13") Weight Crated 14.5 kg. (39 lbs.) Uncrated 17.7 kg. (32 lbs.) July 2019 16500066 ©2019 ACP, Inc.
  • Page 2: Component Testing Procedures

    Fuse block / Filter Power In terminals ........230 VAC assembly Power Out terminals ........230 VAC 20A Fuse Continuity Test Rated 20A 250vac LED Lamp Power across terminals 230vac = light 48 lumens July 2019 16500066 ©2019 ACP, Inc.
  • Page 3: Service Mode

    1) Open door and Press/Hold Pad #3 for 5 seconds or until “SErV” is Displayed 2) Press Pad #1 to display Magnetron Hours in 100’s. 3) Press Pad #3 to display Door Cycles in 100’s July 2019 16500066 ©2019 ACP, Inc.
  • Page 4 13.... 2400 17 ....1700 25 ....2500 9.5 .... 1700 13.5..2500 18 ....1800 27 ....2700 10 ..... 1800 15.... 2700 19 ....1900 30 ....3000 10.5 ..1900 16.5..3000 July 2019 16500066 ©2019 ACP, Inc.
  • Page 5: Wiring And Schematic Diagrams

    Wiring and Schematic Diagrams To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor before servicing, unless testing requires power. July 2019 16500066 ©2019 ACP, Inc.
  • Page 6 Zmax of 0.2 Ohms at the interface point of the user’s supply. The user has to ensure that this device is connected only to a power supply system which fulfills the requirement above. If necessary, the user can ask the public power supply company for the system impedance at the interface point. July 2019 16500066 ©2019 ACP, Inc.
  • Page 7: Electronic Control Operation

    1:48. (1:00 cook cycle x 80% “X2” cook factor = 1:48) Press START key to save. To use this program press “3”. The oven will start operating for 7:05 (1:25 at 70% power + 5:40 at 50% power). July 2019 16500066 ©2019 ACP, Inc.
  • Page 8 Manual Operation OP:81 Allows use of manual time entry and preprogrammed pads OP:90 Allows 10 (0-9) preprogrammed pads Double Digit OP:91 Allows 20 (00-99) preprogrammed pads Operation *Note: Factory setting may vary by model July 2019 16500066 ©2019 ACP, Inc.

This manual is also suitable for:

Rms510ds2Rms510tsuaRms510dsuaRms510tscaRms510tsiaRms510tsaa ... Show all