Direct Expansion Coil Circuiting Data - Carrier 39T Installation, Start-Up And Service Instructions Manual

Central station air-handling units
Table of Contents

Advertisement

39T UNIT SIZE
CIRCUITING TYPE
Airflow (cfm) at 550 fpm
Total Face Area (sq ft)
Tubes in Face
Tube Length (in.)
No. of Circuits — Total
4-Row Coil
Circuit Equivalent Length (in.)
Face-Split Coils
No. of TXVs
No. of Circuits/Distributor*
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Tube Length (in.)
Distributor Nozzle Size†
Row-Split Coils
No. of TXVs
No. of Circuits/Distributor*
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Tube Length (in.)
Distributor Nozzle Size†
6-Row Coil
Circuit Equivalent Length (in.)
Face-Split Coils
No. of TXVs
No. of Circuits/Distributor*
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Tube Length (in.)
Distributor Nozzle Size†
Row-Split Coils
No. of TXVs
No. of Circuits/Distributor*
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Tube Length (in.)
Distributor Nozzle Size†
8-Row Coil
Circuit Equivalent Length (in.)
Face-Split Coils
No. of TXVs
No. of Circuits/Distributor*
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Tube Length (in.)
Distributor Nozzle Size†
Row-Split Coils
No. of TXVs
No. of Circuits/Distributor*
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Tube Length (in.)
Distributor Nozzle Size†
LEGEND
TXV — Thermostatic Expansion Valve (Field-Supplied)
*Where each distributor has the same number of circuits, that number is shown once. When a coil has
an uneven number of circuits per distributor, both values are shown. For example, the upper coil of a
half-circuit size 32 large face area coil has 5 circuits on one distributor and 6 circuits on the other
distributor; the lower coil has 6 circuits on each distributor.
†Factory-supplied distributors have factory-selected nozzle sizes shown. If necessary, replace factory-
supplied nozzles with field-supplied and installed nozzles. Consult Electronic Catalog AHU Builder™
program for correct nozzle selection.
Table 20 — Direct Expansion Coil Circuiting Data
LARGE FACE AREA COILS
07
Quarter
Half
Full
3688
6.7
18
42
15
16
4
9
18
89.9
39.1
24.8
2
2
2
2
4,5
9
7
1
1
1
3
8
8
8
7
7
1
1
8
8
8
11
16
15
4
4
4
2
2
2
2
4,5
9
1
1
7
1
3
8
8
8
7
7
1
1
8
8
8
11
16
15
4
4
4
59.4
29.0
2
2
4,5
9
1
1
1
3
8
8
7
1
1
8
8
16
15
4
4
2
2
4,5
9
1
1
1
3
8
8
7
1
1
8
8
16
15
4
4
79.7
39.1
2
2
4,5
9
1
1
1
3
8
8
1
7
1
8
8
16
15
4
4
2
2
4,5
9
1
1
1
3
8
8
1
7
1
8
8
16
15
4
4
09
Half
Full
Half
Full
4921
5748
8.9
10.5
22
22
46
7
54
8
11
22
11
22
41.7
26.1
47.0
28.7
2
2
2
2
5,6
11
5,6
11
1
1
1
3
1
1
1
3
8
8
8
7
1
3
7
1
3
8
8
8
21
18
21
18
5
5
6
6
2
2
2
2
5,6
11
5,6
11
1
1
1
1
1
3
1
3
8
8
8
7
1
3
7
1
3
8
8
8
21
18
21
18
5
5
6
6
63.4
30.9
71.2
34.9
2
2
2
2
5,6
11
5,6
11
1
1
1
3
1
1
1
3
8
8
8
7
1
3
7
1
3
8
8
8
21
18
21
18
5
5
6
6
2
2
2
2
5,6
11
5,6
11
1
1
1
3
1
1
1
3
8
8
8
7
1
3
7
1
3
8
8
8
21
18
21
18
5
5
6
6
85.0
41.7
47.0
2
2
2
5,6
11
11
1
1
1
3
1
3
8
8
1
1
7
3
3
8
8
15
18
18
5
5
6
2
2
2
5,6
11
11
1
1
1
3
1
3
8
8
1
1
7
3
3
8
8
15
18
18
5
5
6
51
11
13
Double
Half
Full
7173
13.0
24
3
62
5
4
44
12
24
52.2
31.4
2
2
6
12
1
1
1
3
8
8
8
7
1
3
8
8
8
21
18
8
8
2
2
6
12
1
1
1
3
8
8
8
7
1
3
8
8
8
21
18
8
8
79.1
38.8
2
2
6
12
1
1
1
3
8
8
8
7
1
3
8
8
8
21
18
8
8
2
2
6
12
1
1
1
3
8
8
8
7
1
3
8
8
8
21
18
8
8
22.7
52.2
4
2
11
12
1
3
1
3
8
8
8
1
1
3
3
8
8
8
13
18
3
8
4
2
11
12
1
3
1
3
8
8
8
1
1
3
3
8
8
8
13
18
3
8
Double
8
48
25.4
4
12
1
3
8
1
3
8
13
4
4
12
1
3
8
1
3
8
13
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents