Ratings
Table 7 Boiler ratings
Boiler
DOE
model
Heating
number
capacity
(Btuh)
(Note 1)
(Note 2)
CGs-3
57,000
(Note 5)
CGs-4
85,000
CGs-5
112,000
CGs-6
140,000
1. Add "PIN" for natural gas boiler - "PIL" for propane gas boiler.
2. Based on standard test procedures prescribed by the United States Department of Energy.
3. Net I=B=R ratings are based on net installed radiation of sufficient quantity for the requirements of the building
and nothing need be added for normal piping and pickup. Ratings are based on a piping and pickup allowance
Notes
of 1.15. An additional allowance should be made for unusual piping and pickup loads.
4. CGs boilers require special venting, consistent with Category III or IV boiler. Use only the vent materials and
methods specified in CGs vent supplements. CGs boilers may be direct-vented (using 3" diameter air piping)
as specified in the direct vent supplements.
5. As an Energy Star Partner, Weil-McLain has determined that the CGs-3 meets the Energy Star guidelines for
energy efficiency.
CGs boilers for residential radiant panel systems, converted gravity heating systems or other low water tempera-
ture applications should be installed with balancing valves and bypass piping equal to the supply and return
size to avoid excessive fl ue gas condensation due to lower operating water temperatures. For alternate piping,
contact your Weil-McLain sales offi ce. CSA design certifi ed for installation on combustible fl ooring. Tested for
50 psi working pressure.
Part number 550-110-260/0508
0-2,000 feet
2,000-4,500 feet
Input
Output
Input
(Btuh)
(Btuh)
(Btuh)
67,000
57,300
60,300
100,000
85,000
90,000
133,000
112,400
119,000
167,000
140,300
150,300
Net
Boiler
I=B=R
water
Output
ratings
content
(Btuh)
(Btuh)
(gallons)
(Note 3)
51,600
50,000
76,500
74,000
100,600
97,000
126,300
122,000
DOE
(Note 5)
DOE
Vent
Seasonal
size
efficiency
(% AFUE)
(Note 5)
(Note 4)
1.5
85.3
2.1
84.6
2.7
84.0
3.3
83.4
3"
3"
3"
3"
63

Hide quick links: