CAMDEN CM-500SK Instructions Manual page 3

500 user codes keypad

Advertisement

Setting a new master code
1. Enter the master code twice (for the first use the master code default value is 12345). 2 beeps sound and
the LED lights on in orange to confirm entry in programming.
2. Enter
3 then the 5-digit of the new master code. The LED lights off during 1second and an audible beep
indicate that the code has been accepted.
3. Enter # to exit from the programming mode. 2 beeps confirm that you went back to the reading mode.
4. 4 beeps indicate a data computing error.
User numbers group and relays
A user code programmed in the first group addresses (000 to 249) operates relay RL1. A user code programmed in
the second group addresses (250 to 499) operates relay RL2. A user code can be programmed in the two groups.
Therefore, the user code will activate the two relays at the same time.
Setting Time Delays
Enter the master code twice (for the first use the master code default value is 12345). The orange LED and two
beeps sound to confirm entry in the programming mode.
Key-in keypad
time
Programming User
Codes
Door release time
Enter # to exit from the programming mode. 2 beeps confirm that you went back to the reading mode.
4 beeps indicate a data computing error.
Enter
0 then the time in seconds:
10 for 10 seconds up to 99 for 99 seconds.
The LED turns off during 1 second and a beep
sounds to confirm that the time is accepted.
Enter address numbers from 000 to 249 to
operate door #1 and address numbers from 250 to
499 to operate door #2.
Enter
1, then the door release time in seconds:
01 for 1 second up to 99 for 99 seconds.
Enter 00 for a latched output.
The LED turns off for 1 second and a beep
sounds to confirm that the time is accepted.
Enter
2, then the door release time in seconds:
01 for 1 second up to 99 for 99 seconds.
Enter 00 for a latched output.
The LED turns off for 1 second and a beep
sounds to confirm that the time is accepted.