  • Page 1 IP system gate station installation manual I Z M - 8 0 1 C S 4 Thank you for choosing WRT. Please read this manual before using. WRT reserves the right to change specifications or designs described in this manual without notice and obligation.
  • Page 2: Table Of Contents

    Content 1.0 Features& Functions 2.0 Equipment Description Gate Station 3.0 Caution 4~5 4.0 Installation ~ 5.0 Operation 6 22 6.0 Specification 7.0 Terminal Description 8.0 Trouble Shooting 9.0 Wiring 26~28 Content...
  • Page 3: Features& Functions

    & Features Functions 801 intercom systems is composed by building gate station, user door phone, PC and other equipments, which is based on TCP/IP. The system is with the technology of multichannel, every channel can work independently. 1.Luxury design, Max. capacity 400,000 cards,500,000 door phones.   2.Color video.
  • Page 4: Equipment Description

    Gate Station Front View Back View 18V GND UNLOCK J 15 J 24 DOOR MENCI J 2 2 EARTH-GND 1.Microphone 2.LCD Display 3.Keypad 4.Speaker 5.Camera with IR compensation 6. IC card induction zone 7.Camera adjustment 8.Socket for lift control or access control 9.Lightning terminal(GND) 10.Socket for power input+unlock signal output 11.To network switch connector 12.Socket for door contact and door release.
  • Page 5: Caution

    Caution 1. Avoid direct sunlight, extreme temperature, frost, chemical erosion or dust. 2.Please confirm the height to install the station so that the visitor is within the vision of the camera. 3. Cut off the power when installing the system. 4.
  • Page 6: Installation

    Flush mounting 1.Drill holes at the suitable place on the front and the back of the door according to the size (Figure 1). 2.Unscrew 4 screws from Gate Station.(Figure 2) . 125.0mm Iron gate 96.5mm φ3.5 135.0mm (1) (2) Drill a wire hole at the bottom case, insert the transmission wires through the wiring hole, Connecting all wires and press the Gate Station from the front of the door.
  • Page 7 Flush mounting Make a hole in the wall prefer to the dimension of 135 380 67 The bottom of the hole shall be 150cm to 155cm above the ground. Make a wiring hole on the bottom case and insert the wires through it, install the bottom case into the wall and embed it in the cement.
  • Page 8: Operation

    Operation Please note: 1.All the parameters should be configured by appointed or authorized person in case of any data leakage. Admin password must be kept by specially-assigned person for usage or updating purpose. 2.Access control settings of gate station and wall station in the network system should be operated in center guard unit.
  • Page 9 Operation 0 System info 5 Password setting 1 Network setting 6 Function ON/OFF 2 Device No. 7 Time setting 3 Dial Format 8 Access control 4 Device type 9 Language * " " # " Press” to return.Press to next page Press“#”to enter next page: 1 Restore factory setting 1 Restore factory setting...
  • Page 10 Operation 1 Local IP 192 168 100 001 2 Subnet mask 255 255 255 000 3 Gateway 192 168 100 001 4 Center IP 192 168 100 005 5 Back up center 000 000 000 000 6 Master Station 192 168 100 005 7 Sub Master Station 8 Return 000 000 000 000...
  • Page 11 Operation input the parameters, the interface will request to select digit or alphabet(except “0"),for example, ”1:1 2:A”.Press”1" to select serial number as digit, press”2" to select serial number as alphabet. When non-input status, press ”5” ” ” to return to previous menu or exit automatically after 30s Note:Gate Station NO.is composed of 2 digits group NO.+ 3 digits building NO.+2 digits unit NO.+2 digits local NO.,When input should be based on this principle,if digits are not enough ,it...
  • Page 12 Operation screen will prompt that modify successfully and activate the next input box automatically. Non-input status,press”6" or “*” can return to previous menu or exit automatically after 30s. Room NO. Note: Press”*”to clear up the data in the input box or exit input status. Device type Press “4"...
  • Page 13 Operation a. Modify super password Please input new password Input 1- 8 digits new password .Then the screen prompt to confirm super password again. If entered two new super passwords are the same,it will prompt that new super password is modified successfully.
  • Page 14 Operation Input 6 digits new password.Then the screen prompt to confirm unlock password again. If entered two new unlock passwords are the same,it will prompt that new unlock password is modified successfully. Note: Original password is ” 00000000 ”,new password is 6-digit. c.Modify special password Press”3"...
  • Page 15 Operation Function ON/OFF Press 6 ” ” on the basic setting menu, the screen will show: 1 Snapshot ON/OFF 2 Lift ON/OFF 3 Key tone ON/OFF 4 Disarm by card 5 Recording ON/OFF 6 Magnetic alarm 7 Return 0 OFF 1 ON Snapshot ON/OFF: If this function enabled on Gate Station and Guard Center,when door phone call other tenant or Guard Center,Guard Center will snap a picture.
  • Page 16 Operation Time setting: Set the time of Gate Station. Press”7” on the basic setting menu interface, the screen will show: 1Input Year/Month/Day 2011/01/01 Input Hour Min Sec 08:00:00 3Return Press number keys to clear up the data in the input box, input the date and time,press “#” to confirm after finished ,the screen will prompt modified successfully, it means the group data set successfully.
  • Page 17 Operation : a Issue card by swiping Issue card by swiping for tenants. On the “Access Control“interface press “1“ the screen will show: 1 Issue card by swiping Please swipe card..2 Delete card by swiping 3 Issue card by room NO. 4 Delete card by room NO.
  • Page 18 Operation 1 Issue card by swiping 2 Delete card by swiping 3 Issue card by room NO. 4 Delete card by room NO. 5 Return Input 6 digits (3-digit floor NO.+ 3-digit room NO.,for example 001001) the room NO.of tenant. Press”#”again,then swipe the card at induction zone,it means issued successfully,the user could continue inputting other room NO.
  • Page 19 Operation Restore factory setting: All the settings are initialized, please be cautious! Press 1 on the basic setting menu on page 2,the screen will show: ” ” Restore factory setting? 0: NO 1: YES Press 1 then press # all the settings are initialized,Gate Station will restart automatically. ”...
  • Page 20 Operation Press number keys to clear up the data in the input box.Input ”0-9” to set, press”#” to confirm,the screen will prompt that modify successfully and activate the next input box automatically. Press”*” to exit input status. ” ” * Non-input status,press ”3”...
  • Page 21 Operation Press number keys to clear up the data in the input box.Input ”0" or “1" to set digit or alphabet,press ”#” to confirm after each time input,the screen will prompt that modify successfully and activate the next input box automatically. ”...
  • Page 22 Operation Calling Tenants(Divert off): When standby, input room NO. ( 2 digits floor number and 2 digits room NO.), For example, calling room 2 on 3rd floor, input:0302, the screen display the corresponding number at the same time: 0302 Input room NO. “#”...
  • Page 23 Operation Operation Talking, * to hang up Input room NO. “#” for call “00#” for center Visitors can talk with the tenant ,Press “* ” can hang up . If the conversation last over 120 seconds, the system will return to standby state automatically. The tenant can unlock the electric door by pressing the “unlock”...
  • Page 24 Operation Center. You can also leave a message to Guard Center,the message will be delivered to the household. Calling Center: Press“00#”,you can call the Center(sequence of call:Master Station>Sub Master Station>Guard Center>Back up Guard Center) If the center is free, the screen will show: * to hang up Calling Input room NO.
  • Page 25 Operation Operation Unlock,please close the door Input room NO. “#” for call “00#” for center If the device is Gate Station,tenant can use special password to unlock.The method is to input“ * ” Room NO.+ password + “ #”. When tenant use special password to unlock,input room NO. should according to dial format.For example,dial format is 1-digit floor NO.
  • Page 26: Specification

    Specification Direct Voltage +18VDC ≤290 Static Current ≤ Working Current Operating Temperature - 3 0 C~+ 5 5 C 4 5 %~9 5 % Humidity ≤5 % Distortion ≤3 0 m V Sensitivity 5-16U.500 wire Automatic backlight compensation Camera Signal System 320(RGB)x240 Resolution 4 0 inch...
  • Page 27: Terminal Description

    Terminal Description Description Terminal Marks +, Power supply input supply DC 18V for the station Power supply input- UNLOCK Unlock signal output, 12V when unlock DOOR Unlock signal input MENIC To door contact 485A data wire 485B data wire To network switch Terminal Description...
  • Page 28: Trouble Shooting

    Trouble shooting Description Solution C h e c k 1.Check the power supply Connect wires between Gate Station and G a t e S t a t i o n 2.Check the wire connection between Gate d o e s n o t w o r k power supply correctly Station and power supply 1.Check the network port and connection...
  • Page 29: Wiring

    Wiring Back view Wire of power supply Wire of 1 8 V electric lock G N D P U S H Electric lock H D - V 1 8 To network switch To lift controller or access control 18V GND UNLOCK J 1 5 DOOR...