Table of Contents

Advertisement

PDP20 F 4 mag
Series connection
X1, X2: Terminal block
Grey area: Control cabinet
24 V
0 V
X1

Operation

When the supply voltage is applied, the device checks whether the device is operating as a
stand-alone device or in series with another PDP20 F 4 mag.
The unit is ready for operation when the Power LED is permanently lit.
Operating Manual PDP20 F 4 mag
24737-EN-03
F1
A1
T0
A2
T0
T0
T0
T0
T1
T1
T1
T1
T1
O0
I10
O1
I11
I20
I21
I30
PDP20 F 4 mag
I31
I40
I41
NOTICE
– No sensor should be connected between safety outputs O0 and O1
of the first PDP20 F 4 mag and inputs I40 and I41 of the second
PDP20 F 4 mag. With a series connection, only safety output O0/O1
may be connected to the cascading inputs I40 - I41.
– The signal output SO indicates the state of the connected sensors.
The state at input circuit I40 - I41 is not considered.
NOTICE
The safety function should be checked after initial commissioning and each
time the plant/machine is changed. The safety functions may only be
checked by qualified personnel.
F1
A1
X2
A2
T0
T0
T0
T0
T1
T1
T1
T1
I10
I11
I20
I21
I30
PDP20 F 4 mag
I31
I40
I41
11