  • Page 1 Ethernet Switch ESUG4P-PG2 User Manual...
  • Page 2: Table Of Contents

    ................... 11 TESTING SYSTEM EXAMPLE ............... 12 DIMENSIONS ................12 WARRANTY ................13 ................13 ARRANTY NFORMATION A ITE .................... 14 LASS FCC ....................... 14 INSTRUCTION OF DISASSEMBLY ............14 Manual-ESUG4P-PG2_Series_HW-Rev1201 Copyright © KBC Networks Ltd. Page 2 of 15 www.kbcnetworks.com...
  • Page 3: Overview

    1.1.1 ESUG4P-PG2 The ESUG4P-PG2 provides connectivity for up to four, 10/100/1000 RJ45 twisted pair copper ports which are capable of simultaneously supplying IEEE802.3at PoE and two gigabit SFP ports. Each of the four, 10/100/1000 RJ45 ports supports a self-adaptive function allowing it to be configured to 10Base-T, 100Base-TX or 1000Base-T, full or half duplex operation mode.
  • Page 4: Technical Specification

    Mean Time Between Failure >300,000 hours Mechanical Dimensions (W x H x D) 60mm x 152mm x 105mm 2.35” x 5.98” x 4.13” Protection class rating IP30 850g Weight 1lb 14oz Manual-ESUG4P-PG2_Series_HW-Rev1201 Copyright © KBC Networks Ltd. Page 4 of 15 www.kbcnetworks.com...
  • Page 5: Installation

    Please contact you dealer or distributor if a part is missing or damaged. 2.2 Configurations Products are available in either DIN rail or wall-mount packages, with the following configurations: Product Type DIN Rail Wall-mount ESUG4P-PG2   Manual-ESUG4P-PG2_Series_HW-Rev1201 Copyright © KBC Networks Ltd. Page 5 of 15 www.kbcnetworks.com...
  • Page 6: Physical Connections

    Ethernet Switch User Manual 2.2.1 Physical Connections Top View Manual-ESUG4P-PG2_Series_HW-Rev1201 Copyright © KBC Networks Ltd. Page 6 of 15 www.kbcnetworks.com...
  • Page 7: Installation Method

    Each switch supports IEEE802.3x so the optimum transmission mode (either half-duplex or full-duplex) and data rate (either 10Mbps, 100Mbps or 1000Mbps) will be selected automatically. Manual-ESUG4P-PG2_Series_HW-Rev1201 Copyright © KBC Networks Ltd. Page 7 of 15 www.kbcnetworks.com...
  • Page 8: Sfp Ports

    PWR1: + Note: If only using one power source, connect pin 1 to pin 5 and pin 2 to pin 6 otherwise the Power Fault Alarm will be lit. Manual-ESUG4P-PG2_Series_HW-Rev1201 Copyright © KBC Networks Ltd. Page 8 of 15 www.kbcnetworks.com...
  • Page 9: Fault Alarm Contact

    The fault alarm contacts are in the middle of the 6 pin, screw block terminal on pins 3 & 4. An open circuit will occur if a power failure is detected. P-Fail 24Vdc, 1A resistance Load External power Fig 2.2 Fault Alarm Contacts Manual-ESUG4P-PG2_Series_HW-Rev1201 Copyright © KBC Networks Ltd. Page 9 of 15 www.kbcnetworks.com...
  • Page 10: Led Status

    Port operating at 10/100M Effective network connection has been established for the port Upper Data traffic is passing through the port No effective network connection has been established for FLASH the port Manual-ESUG4P-PG2_Series_HW-Rev1201 Copyright © KBC Networks Ltd. Page 10 of 15 www.kbcnetworks.com...
  • Page 11: Troubleshooting

    100Ω Cat 5 cable or above for 100Mbps connections 100Ω Cat 5e cable or above for 1000Mbps connections Twisted pair connection must not exceed 100m (328 feet)  See section 2.7 for LED status indicators. Manual-ESUG4P-PG2_Series_HW-Rev1201 Copyright © KBC Networks Ltd. Page 11 of 15 www.kbcnetworks.com...
  • Page 12: System Example

    Ethernet Switch User Manual 4 System Example Figure 4.1 ESUG4P-PG2 Typical System Application 5 Dimensions Manual-ESUG4P-PG2_Series_HW-Rev1201 Copyright © KBC Networks Ltd. Page 12 of 15 www.kbcnetworks.com...
  • Page 13: Warranty

    KBC, to be defective in material or workmanship, KBC will repair or replace such part or portion at KBC’s option. The warranty period on the repaired or replaced part or portion of this product shall be limited to the unexpired term of the original warranty.
  • Page 14: Classa Ite

    2. Remove cover plate. 3. Remove tightening screws for printed circuit board (PCB). 4. Take out all PCBs. Notice: When a product reaches the end of its life – return to KBC. Manual-ESUG4P-PG2_Series_HW-Rev1201 Copyright © KBC Networks Ltd. Page 14 of 15...
  • Page 15 KBC Networks 25691 Atlantic Ocean Drive Suite 3B Lake Forest, CA 92630 U.S.A Americas Phone: 1-949-297-4930 Fax: 1-949-297-4933 KBC Networks Ltd., EMEA KBC Networks Ltd. Barham Court Teston, Maidstone Kent, ME18 5BZ United Kingdom Phone: +44(0)1622 618787 Fax: +44(0)20 7100 8147 Email: info@kbcnetworks.com...