v Do not remove the load source from a secondary partition you want to keep.
v Every logical partition must have access to an alternate IPL IOP/device. It can be dedicated or
switchable.
v Every logical partition must have a load source disk.
To add a new logical partition follow these steps:
1. Power down all of the secondary partitions.
2. Perform an initial program load (IPL) of the entire system in manual mode to dedicated service tools
(DST).
3. Verify that the secondary partitions are powered down.
4. Remove the processing resources from the primary partition or secondary partitions for the new
secondary partition.
5. Remove the I/O resources from the primary partition or secondary partitions for the new secondary
partition.
6. At the Work with System Partitions display, select option 5 (Create a new partition).
7. Press F9 for a list of limits.
8. Provide the required information for:
v Partition name. (A partition name can be any word (except PRIMARY), not exceeding 8 characters
(A - Z and 0 - 9)).
v Number of partition processors.
v Size of main storage (MB).
v Partition interactive performance.
v Connect to system Virtual OptiConnect.
v Connect to system HS-Connect (High Speed Link).
9. Press Enter.
If you have entered a value that is out of range, you will receive a message to change your numbers.
You can also adjust limits for the following:
v Processors.
v Size of main storage (MB).
v Partition interactive performance.
10. If you have had to make adjustments, press Enter after you finish. The Add I/O Resources display is
next.
11. At the Add I/O Resources display, type either a 1 (Own dedicated), 2 (Own bus shared), or 3 (Use
bus shared) beside your selected bus resource. Type 1 beside your selected IOP resources.
12. Press Enter to go to the Confirm Add I/O Resources display.
If the expected resources are not on the list, return to the Add I/O Resources display. Make sure that
you have added the correct resources.
13. Press Enter to confirm your selection and go to the Select Load Source Resource display. Press F12
to return to the previous display if you wish to change your choices. If your selection was successful,
a confirmation notice will appear at the bottom of the display.
14. At the Select Load Source Resource display, type 1 (Select IOP) next to the desired resource and
press Enter.
If the expected resource is not on the list, return to the Add I/O Resource display. Make sure that you
have added the correct resources. If the expected resource is already on the Add I/O Resource
display list, consult the AS/400 Logical Partitions Hardware Planning Guide
requirements.
32
AS/400e: Logical Partitions: Managing
for hardware

Advertisement