Summary of Contents for XpressFill XF4400

  • Page 1 XpressFill XF4400/XF2200...
  • Page 3 All repairs must be performed by a qualified Service Technician or with the approval from an XpressFill Technician. Only original factory replacement parts should be used. Electrical shock or fire could result if the electrical supply for the can filler covered in this manual is not correctly installed or if the can filler has been improperly grounded.
  • Page 4: Safety Warnings

    Safety Warnings...
  • Page 5 XPRESSFILL Systems LLC | Table of Contents t n I d o r t c u n o i Set Up Your Filler o r T l b u h s e t o o g n i a e l...
  • Page 6 | XPRESSFILL Systems LLC Introduction XpressFill Product Guarantee workmanship.
  • Page 7 XPRESSFILL Systems LLC | XPRESSFILL Systems LLC | Set Up Your Filler 2. Unscrew the adjustment knobs holding the shelf to the machine. 3. Place a can on the shelf and raise the shelf into position to a point where the level sensor is where you want the level of the liquid to be in the can.
  • Page 8 | XPRESSFILL Systems LLC lower are contacted by the liquid simultaneously. 9. Place your cans, two at a time, on the shelf, centered under the right two or left two spouts. For spouts 1 and 2, turn on the Fill Switch located on the left side of the machine about 3” from the top (about 3 seconds, which can be adjusted) and then the fill with your carbonated product.
  • Page 9 | XPRESSFILL Systems LLC placed on foam before seaming.
  • Page 10: Troubleshooting

    | XPRESSFILL Systems LLC Troubleshooting product, please contact XpressFill at the number listed on the front of this manual. We are always happy to assist you. full can at the point there is contact between the spouts. Excessive Foaming higher level of CO2 in your product and minimizing the amount of foam. We recommend no...
  • Page 11: Cleaning And Sanitizing

    XPRESSFILL Systems LLC | Cleaning & Sanitizing Cleaning the liquid flow path is to first clean the liquid flow path. Connect the hose to your cleaning/sanitizing solution in a pressurized container. Place an empty can under each of your spouts and activate the fill switch.
  • Page 12 | XPRESSFILL Systems LLC Additional Information Our fillers use “Push-To-Connect” type connectors which are common in the beverage industry. connection is secure. Push the collet in to remove tubing 265 Prado Road, Tel:...
  • Page 13 (do not remove screws) and pop the spare fuse holder toward you, then replace the fuse. XpressFill Part No. 20002 - Bussmann Series by Eaton, Model BK/GDB-2A, 5mm x 20mm Delay Timer Adjustment...
  • Page 14 XPRESSFILL Systems LLC | Fluid Solenoid Deep Cleaning Instructions Remove the Solenoid from the machine. Use the release tool to disconnect the push-to-connect fittings. Loosen the hex nut at the top of the coil assembly. Unscrew the base from the coil assembly. Use a screwdriver as needed.
  • Page 15 XPRESSFILL Systems LLC | CO2 Purge Solenoid Deep Cleaning Instructions Remove the Solenoid from the machine. Use the release tool to disconnect the push-to-connect fittings. You do not have to remove the tube from the solenoid. Slide off the clip from the top of the coil assembly.

This manual is also suitable for:

Xf2200