  • Page 1 XpressFill XF460/XF260...
  • Page 2: Safety Warnings

    Safety Warnings...
  • Page 3 Severe product damage and/or injury could result from the use of unqualifi ed Service Technicians or non-original replacement parts. All repairs must be performed by a qualifi ed Service Technician or with the approval from an XpressFill Technician. Only original factory replacement parts should be used.
  • Page 4 fi rst consulting XpressFill Systems LLC.
  • Page 5 You then can refi ne your level by changing the time. 4. To change the fi ll time on your XF460, simply follow these steps: Each digit can be changed with the numbered push button below the display.
  • Page 6 XPRESSFILL Systems LLC | Optional Gas Sparge If your fi ller has the gas sparge option, fi rst make sure you have the hose going into the fi ller safely e recommended pressure is 20 - 30 psi. To fl ush your bottle, simply push the “Gas” button for the desired length of time (1-3 sec) before you...
  • Page 7: Troubleshooting

    I Have Uneven Fill Levels Please note that the XF460/260 is a volumetric filler, not a level filler. You might encounter different fill lines in your bottles due to differences in your bottles. Your bottle might have the same weight, but have slight variances in wall thickness, neck size, punt, etc.
  • Page 8 XPRESSFILL Systems LLC | I Need A Spare Fuse ere is a spare fuse in the power entry connector (where the power cord plugs in). Unplug the machine and set screwdriver on the notch (do not remove screws) and pop the spare fuse holder...
  • Page 9 | XPRESSFILL Systems LLC Cleaning Please note: You are responsible to ensure that your XpressFill fi ller is clean and does not contaminate your product. We recommend a through cleaning before and after your bottling run. Simply use a K-Meta, Na-Meta cleaning solution (easily obtainable at supply stores), or simple baking soda as your cleaning solution.