6. Installer parameters
To enter installer parameters please follow steps below. Please refer to parameters table description before any changes. Use
up or down between all parameters. Every change/selection confirm by
1
Hold
+
seconds to enter the installer mode.
3
Press
dXX
Function
Control method
d01
temperature
d02
Offset temperature
Using a floor temperature
d03
sensor (S1, S2)
External sensor
used for air
or floor temperature
d04
measurement
(Function is active,
when d03=1)
buttons for 5
+
button to confirm.
Parameter
Values
This parameter defines the algorithm of the room temperature control.
0
1
2
-3.0°C to
+ 3.0°C
0
1
0
1
button:
2
Use
4
Select installer parameter by or
buttons. Use
change parameter value.
Confirm choice by
PWM (Pulse-width modulation) algorithm ensures reduction of overdrive
states and economic operation of the system. It is an advanced algorithm
designed to precisely maintain room temperature.
SPAN ± 0.5°C (± 1°F)
SPAN ± 1°C (± 1.5°F)
Offset room temperature measuring is a function which allows user to
recalibrate internal thermostat's temperature sensor by a given number of
degrees (in the range from -3,0 °C to 3,0 °C in 0,5°C steps).
Sensor is connected
Thermostat measures the temperature only on the
external sensor
The sensor is used as a protection against
overheating the floor
or
to choose
code „49".
3
or
buttons to
button.
Description
No sensor
or
buttons to move
Default
Values
0
0.0°C
0
0
25
Need help?
Do you have a question about the Salus Controls VS30W and is the answer not in the manual?