INSTALLING DYNAPACK

IMPORTANT
The Dynapack condensate drain
system is designed to be installed
in a conditioned space. To
prevent freezing of the drain
condensate in the P-Trap, the
installation location should not
be exposed to freezing
conditions. In installations where
the drain system is exposed to
freezing conditions, we offer an
optional heated P-Trap which is
available for purchase. The part
number for the heated P-Trap
installation kit is K/10348 and the
steps for installation are outlined
in Appendix A.
Suburban DynaPack A&E Manual 07/2019 Rev.6
INSTALLING DYNAPACK
The DynaPack units are vertical packaged units featuring gas fired heating
with electrical air conditioning. The DynaPack unit has been safety certified
by Intertek Testing Services to comply with the national safety codes of the
USA and Canada. All DynaPack units are certified to operate on natural gas.
LP gas is available for S Series only.
The DynaPack unit is NOT certified for installation in a mobile home .
Installations in the USA must be in accordance with city, county, or state codes
and regulations. If local codes do not apply then the installation must be made in
accordance with the National Fuel Gas Code and the National Electrical Code.
This product is a general purpose heating and cooling product to be installed in
a conditioned closet. For hotel guestroom applications, sound treatment on the
closet walls and doors is required to meet the recommended ASHRAE sound
criterion and a ducted supply and return are recommended for best sound
performance.
Installations made in Canada likewise must be in accordance with city, provincial,
or national codes or the current version of CANI-B149 Installation Code.
WARNING! In the state of Massachusetts: This product must be
installed by a licensed Plumber or Gas Fitter. When flexible
connectors are used, the maximum length shall not exceed 36".
When lever-type gas shutoffs are used, they shall be T-handle type.
The outdoor fan discharge or the condenser air intake cannot be connected to
field fabricated ducting. This unit can only be installed using the factory
supplied wall sleeves.
MINIMUM OPERATIONAL CLEARANCES
The DynaPack unit is approved for indoor installation only and must be
installed with one of the factory supplied wall sleeves. The unit is intended to
be installed in a closet or equipment room. The unit is certified for 0"
clearance to the cabinet sides, cabinet back and the first 3 feet of the supply
FIGURE 1
duct. However, for accessibility reasons it is
recommended to maintain at least 1"
clearance on the sides for proper installation
and servicing. For closet installations allow 4"
clearance from the unit door panels to the
closet door. For equipment room installations
allow 24" clearance from the unit door
panels to a wall for servicing.
The wall sleeve is intended to be installed flush
with the exterior wall. The outside grille would
then be mounted immediately inside the
sleeve opening, flush with the outside of the
sleeve. The installer can apply casing around
the grille for a more pleasing appearance. The
unit, wall sleeve, and grille are required to
be installed certain distances for
adjacent doors, operable windows and
shrubbery.
CAUTION: The unit should be installed level
front to back and side to side. Adjust front
leveling legs
as necessary.
10
(continued on next page)
See Figure 2.