Ac/dc electromagnets and permanent magnets gauss meter

Advertisement

®
MF-30K
AC/DC Electromagnets and
Permanent Magnets Gauss Meter
User's Manual
HB4MF30K0000

Advertisement

Table of Contents
loading

Summary of Contents for LATNEX MF-30K

  • Page 1 ® MF-30K AC/DC Electromagnets and Permanent Magnets Gauss Meter User’s Manual HB4MF30K0000...
  • Page 2: Table Of Contents

    Contents: Introduction ............1 Accessories............1 Safety Precaution:..........2 Instrument Description: ........3 Operation: ............4 Zeroing 5 Peak Measurement ........5 Relative Value Measurement......6 Turn on backlight........6 Manual Record for One Log .......6 Auto Record ..........6 Read the record data from RAM....7 Data Hold ...........7 The Max./Min.
  • Page 3: Introduction

    ® MF-30K 1 Introduction  Measurement for the magnetic field generated from Direct Current (DC, with display by N/S Magnetic polarity) or Alternating Current (AC in 40-500Hz).  Measurement for the residual magnetic after processing of mechanical parts  Measurement for the magnetic field strength of magnetic applications ...
  • Page 4: Safety Precaution

    ® MF-30K 3 Safety Precaution: Caution! Please refer to this manual. Improper use may damage the meter and its components. Complies with European Directive.  Do not operate in environments with flammable gas or humid environments.  Operating altitude: up to 2000M.
  • Page 5: Instrument Description

    ® MF-30K 4 Instrument Description: Data hold Power Backlight button SET/Peak value hold Read the record data from RAM (R-M)/Left Set to Zero (Zero)/ Relative Value (REL) AC/DC switch/Up Manual range mode/Automatic range mode Manual record (REC)/ Auto record (LOG) 10.
  • Page 6: Operation

    ® MF-30K 5 Operation: Press to turn on or turn off. Remove the cap of probe. Move the HALL ELEMENT which is located on the tip of probe close to the magnet under test and start measuring. Please refer to Fig. 1.
  • Page 7: Zeroing

    ® MF-30K 5.1 Zeroing Move the probe away from the magnetic field and press , ZERO will appear on the LCD. After zeroing completed, the ZERO disappears. If more than 3G or 0.3mT, will appear to prevent from erroneous zeroing the value in measuring. (from If more than 3G or 0.3mT,...
  • Page 8: Relative Value Measurement

    ® MF-30K 5.3 Relative Value Measurement Press and hold for ≥2 seconds to start Relative Value Measurement. The difference between the two magnetic fields can be compared here. For instance, the 1 magnetic field is measured to be 100. At the time, press “REL”...
  • Page 9: Read The Record Data From Ram

    ® MF-30K 5.7 Read the record data from RAM Press for the reading mode, and appears on the LCD. Press to select the log number for reading. Press and hold quit this mode. 5.8 Data Hold Press to enable or disable the data hold function.
  • Page 10: Manual Range Mode/Automatic Range

    ® MF-30K 5.12Manual range mode/Automatic range mode Press to operate in the manual range mode with the LCD showing . This can change into two different range modes. Press and hold for ≥ 2 seconds to return to automatic range mode with LCD showing 5.13AC/DC Switching magnetic field...
  • Page 11 ® MF-30K Step 4. Set up the lower limit (Max.) for alarm GO/NO-GO 1. The default value is 0G (0.0mT). Press to modify and setup the default value. 2. Again, press to go to Step 5. If the min. value is more than the max.
  • Page 12: Software Installation

    ® MF-30K Press to select where the default value is 。 If the record is not cleared, press again to return to the measurement mode when the LCD shows is selected, press to return to the measurement mode and clear the record while LCD shows "CLEAR".
  • Page 13 ® MF-30K Execute the PC desktop software program:  Double-click the left mouse button on the desktop program (Thermometer Meter) to execute the desktop program.
  • Page 14: General Specifications

    ® MF-30K 7 General Specifications: Liquid crystal display (LCD) of 5 digits with the  displaying value up to 30000. Backlight display. The backlight is manually  turned on (it will turn off automatically after turned on for 30 seconds) and turned off. If connected via an external power supply, the backlight will lit and stay on;...
  • Page 15 ® MF-30K Automatic recording: up to 7000 logs where the  record interval shall be setup with PC. " ": detection for battery low  Battery life: Approximately 100 hours.  Operation temperature and humidity: 5°C to 40°C (41°F ...
  • Page 16: Electrical Specification

    ® MF-30K 8 Electrical Specification: Accuracy is indicated as [% rdg + dgt] at 23°C ± 5°C with RH < 80%. Specifications Range Resolution Accuracy 300.00 mT 0.01 mT ±(4% + 10dgt) DC milli Tesla 2000.0 mT 0.1 mT 2000.1 ~ 0.1 mT...
  • Page 17: Maintenance Or Repair

    ® MF-30K 9 Maintenance or Repair “ ” 1. When the When symbol is displayed on the LCD, it means that there is insufficient power; please change the battery immediately in order to ensure its accuracy. 2. Do not place the meter in locations that have high temperature, humidity or that are exposed to direct sunlight.