Radio Equipment Directive (Red) 2014/53/Eu; Ce Electromagnetic Compatibility (Emc) Conformity - Siemens SITRANS L Series Compact Operating Instructions

Radar level transmitters with profibus pa
Hide thumbs Also See for SITRANS L Series:
Table of Contents

Advertisement

Safety information
2.1 Preconditions for safe use
2.1.7

Radio Equipment Directive (RED) 2014/53/EU

For the receiver test that covers the influence of an interferer signal to the device, the
performance criterion has at least the following level of performance according to ETSI TS
103 361 [6]:
● Performance criterion: measurement value variation Δd over time during a distance
measurement
● Level of performance: Δd ≤ ±50 mm
2.1.8

CE Electromagnetic Compatibility (EMC) Conformity

This equipment has been tested and found to comply with the following EMC Standards:
EMC Standard
CISPR 11:2009 + A1:2010/EN
55011:2009 + A1:2010, Class B
EN 61326:2013
(IEC 61326:2012)
EN61000-4-2:2009
EN61000-4-3:2006 + A1:2008 + A2:2010
EN61000-4-4:2004 + A1:2010
EN61000-4-5:2006
EN61000-4-6:2010
EN61000-4-8:2010
12
Title
Limits and methods of measurements of radio dis-
turbance characteristics of industrial, scientific, and
medical (ISM) radio-frequency equipment.
Electrical Equipment for Measurement, Control and
Laboratory Use – Electromagnetic Compatibility.
Electromagnetic Compatibility (EMC) Part 4-2: Test-
ing and measurement techniques – Electrostatic dis-
charge immunity test.
Electromagnetic Compatibility (EMC) Part 4-3: Test-
ing and measurement techniques – Radiated, radio-
frequency, electromagnetic field immunity test 2006 +
A1:2008 + A2:2010.
Electromagnetic Compatibility (EMC) Part 4-4: Test-
ing and measurement techniques – Electrical fast
transient/burst immunity test.
Electromagnetic Compatibility (EMC) Part 4-5: Test-
ing and measurement techniques – Surge immunity
test.
Electromagnetic Compatibility (EMC) Part 4-6: Test-
ing and measurement techniques – Immunity to con-
ducted disturbances, induced by radio-frequency
fields.
Electromagnetic Compatibility (EMC) Part 4-8: Test-
ing and measurement techniques – Power frequency
magnetic field immunity test.
SITRANS LR250 with PROFIBUS PA