Electrical Connection - BOMANN EBK 958 Operating Instructions Manual

Built-in glass-ceramic hob
Table of Contents

Advertisement

Electric Connection
WARNING
Danger from electrical current!
Connection to the mains may only be performed by authorized
certified electrician in compliance with the relevant VDE regula-
tions.
► Have the electric connection performed only by an authorized
specialist.
► Before the start of work, disconnect and isolate all poles of the
input line.
Connection Conditions
• Before making the connection, confirm that the power supply conforms to
the information on the name plate on the underside of the appliance.
• The supply line must have an isolating device for all poles with a contact
gap of at least 3 mm in the house installation (fuses, circuit breaker, or
contactor).
• The appliance must be grounded via an earth conductor.
• A rubber-sheathed cable H05VV-F with wire end ferrules and correspond-
ingly rated cross section must be used as the mains connection cable
(EN60335: 3 x 6 mm
• Protection against accidental contact must be guaranteed. For increased
safety, an FI circuit breaker with a trip current of 30 mA should be connect-
ed between the appliance and the mains.
• Connection to a domestic socket (230 V/16 A) and the use of multiple
sockets is not permitted.
• The connection cable must not be bent or clamped.
Mains Connection
The appliance is designed for two connection types (refer to the following fig-
ure):
2
2
, 5 x 2.5 mm
or 4 x 2.5 mm
- 29 -
2
).