System error message indicates problem
l
Device connected to the port not working
l
Action
1.  Enter the System Setup program and check that the USB ports are enabled. See "Using the System Setup Program" in the User's Guide for instructions.
2.  If possible, swap the interface cable with a known working cable.
If the problem is resolved, the interface cable must be replaced.
3.  Disconnect all USB devices, and connect the malfunctioning device to the other port.
If the problem is resolved, the USB port may be defective. See
If the problem is not resolved and there is only one USB device connected to the system, go to step 5.
4.  Swap the USB device with a comparable device.
If the problem is resolved, the suspect USB device must be replaced. See
Troubleshooting the Integrated NICs
Problem
Integrated NICs cannot communicate with the network
l
Action
1.  Check the two indicators on the left and right corners of the NIC connectors on the system's back panel (see Figure 5-1).
The green link indicator on the left side of the connector shows that the adapter is connected to a valid link partner. The amber activity indicator is on if
network data is being sent or received.
If the link indicator is not on, check all cable connections.
l
Try changing the auto-negotiation setting, if possible.
l
Try another port on the switch or hub.
l
Figure 5-1. NIC Indicators
2.  If the activity indicator does not light, the network driver files might be damaged or deleted.
Check the drivers and remove and reinstall the drivers if applicable.
You must reboot your system for the reinstalled drivers to become active.
3.  Make sure the appropriate drivers are installed and the protocols are bound.
4.  Enter the System Setup program and confirm that the NICs are enabled. See "Using the System Setup Program" in the User's Guide for instructions.
Responding to a System Management Alert Message
The optional system management applications monitor critical system voltages and temperatures, the system cooling fans, and the status of the hard drives in
the system. Alert messages appear in the alert log window. For information about the alert log window and options, see your system management software
documentation.

Inside the System

In Figure 5-2, the system doors are open and the bezel is removed to provide an interior view of the system.
Figure 5-2. Inside the System
 
"Getting
Help" for instructions on obtaining technical assistance.
"Getting
Help" for instructions on obtaining technical assistance.