Dell PowerEdge 1650 Installation And Troubleshooting Manual page 18

Hide thumbs Also See for PowerEdge 1650:
Table of Contents

Advertisement

system board - please run SETUP program
CPUs with different cache sizes detected
Decreasing available memory
Diskette drive 0 seek failure
Diskette read failure
Diskette subsystem reset failed
ECC memory error
Embedded server management error
Embedded server management is not present
Error: Dell Remote Access Card initialization
failure
Gate A20 failure
Hard disk controller failure
Hard disk read failure
Invalid configuration information - please run
SETUP program
Invalid memory configuration detected.
Potential for data corruption exists!
Invalid NVRAM configuration, resource re-
allocated
I/O parity interrupt at address
Keyboard controller failure
Keyboard data line failure
Keyboard stuck key failure
Keyboard clock line failure
Keyboard failure
Memory address line failure at address, read
value expecting value
Memory high data line failure at start address
to end address
Memory high address line failure at start
address to end address
Memory double word logic failure at start
address to end address
Memory odd/even logic failure at start address
to end address
Memory write/read failure at address, read
value expecting value
Memory parity failure at start address to end
address
Setup program, NVRAM_CLR jumper is
installed, or faulty system battery.
Two different types of microprocessors
are installed.
One or more memory modules improperly
seated or faulty.
Faulty or improperly inserted diskette,
incorrect configuration settings in System
Setup program, loose diskette interface
cable.
Faulty diskette, or faulty or improperly
connected diskette drive.
Faulty diskette/CD drive controller
(defective system board).
Improperly seated or faulty memory
modules.
Embedded server management memory
may be temporarily corrupted.
Defective server management card or
system board.
Faulty keyboard controller (defective
system board).
Incorrect configuration settings in System
Setup program, improperly connected
hard drive, faulty hard-drive controller
subsystem (defective system board), or
loose power cable.
Incorrect configuration settings in System
Setup program, NVRAM_CLR jumper is
installed, or faulty system battery.
Memory modules are not installed in
matched pairs.
System configuration data has been
ignored.
Expansion card(s) is improperly installed
or faulty.
Defective keyboard/mouse controller
(defective system board).
Keyboard cable connector is loose or
improperly connected; defective
keyboard; defective keyboard/mouse
controller (defective system board).
Faulty or improperly seated memory
modules or defective system board.
Improperly seated or faulty memory
modules.
the System Setup Program" in the User's Guide. Remove
the NVRAM_CLR jumper. See
Figure A-2
Replace the battery. See
"Replacing the System
"Installing System Board Options."
Install a correct version of the microprocessor so that both
microprocessors have the same level 2 cache size. See
"Adding or Replacing a
Microprocessor" in "Installing
System Board Options."
Remove and reseat the memory modules. See
Memory
Modules" in "Installing System Board Options." If
the problem persists, replace the memory modules. If the
problem persists, see
"Getting
Help."
Replace the diskette. Run the System Setup program to
correct the diskette drive type. See "Using the System
Setup Program" in the User's Guide. Check that the
diskette drive interface cable is connected correctly. See
"Installing
Drives."
Check that the diskette drive interface cable is connected
correctly. See
"Installing
Drives."
Replace the system board. See
"Getting
Remove and reseat the memory modules. See
Memory
Modules" in "Installing System Board Options." If
the problem persists, replace the memory modules. If the
problem persists, see
"Getting
Help."
To clear the embedded server management memory, shut
down the system, disconnect the power cord(s), wait
approximately 30 seconds, and then reconnect the power
cord(s) and restart the system. If the problem persists,
see
"Getting
Help."
Replace the expansion card. See
"Installing Expansion
Cards" in "Installing System Board Options." If the problem
persists, replace the system board. See
Replace the system board. See
"Getting
Check the hard-drive configuration settings in the System
Setup program. See "Using the System Setup Program" in
the User's Guide. Reinstall the hard drive. See
Drives." Check the interface cable and power cable
connections to the backplane board. See
Drives."
Check the System Setup configuration settings. See "Using
the System Setup Program" in the User's Guide. Remove
the NVRAM_CLR jumper. See
Figure A-2
Replace the battery. See
"Replacing the System
"Installing System Board Options."
Install memory modules in matched pairs. See
Memory" in "Installing System Board Options."
Check the System Setup configuration settings. See "Using
the System Setup Program" in the User's Guide.
Reinstall the expansion card(s). See
Cards" in "Installing System Board Options." If the problem
persists, replace the expansion card(s).
Replace the system board. See
"Getting
Check the keyboard cable connection. Replace the
keyboard. If the problem persists, replace the system
board. See
"Getting
Help."
Remove and reseat the memory modules. See
Memory
Modules" in "Installing System Board Options." If
the problem persists, replace the memory modules. If the
problem persists, see
"Getting
Help."
Remove and reseat the memory modules. See
Memory
Modules" in "Installing System Board Options." If
the problem persists, replace the memory modules. If the
for jumper location.
Battery" in
"Removing
Help."
"Removing
"Getting
Help."
Help."
"Installing
"Installing
for jumper location.
Battery" in
"Installing
"Installing Expansion
Help."
"Installing
"Installing

Advertisement

Table of Contents
loading

Table of Contents