Brewer Features - Grindmaster Precision Brew Operator's Manual

Single cup brewing system
Table of Contents

Advertisement

Brewer Features

Cup Volume:
The brewer is factory preset to dispense approximately 9 fluid ounces (266 ml) of
water without a coffee pod installed. Depending on the type of coffee pod used, the
coffee pod will absorb approximately 1 fluid ounce (30 ml) of water during the brew
cycle. The resulting volume in the cup will be approximately 8 fl. oz. (237 ml).
Important: To prevent overflow, cups used for brewing coffee into must be greater in
volume than the amount of coffee being brewed. For example, an 8 fluid ounce
(237 ml) brew volume will dictate the use of a minimum 10 fluid ounce (296 ml) cup.
This brewer can be manually adjusted to deliver more or less volume. To dispense a
cup with less volume than the preset 8 fl. oz. (237 ml), push the BREW button during
dispensing to stop dispensing.
To dispense a larger cup volume than the preset 8 fl. oz. (237 ml), allow the brewer to
dispense one complete brew cycle, replace the pod, shut the brew chamber door and
push the green BREW button. You may interrupt the brew cycle to get the desired cup
volume by pushing the BREW button during dispensing, or you can allow the second
brew cycle to complete for a 16 fl. oz. (474 ml) serving.
Brew Strength Control:
Changes coffee brew strengths (mild, medium or strong) or selects tea cycle.
Automatic Time-Out Feature:
The brewer will shut itself Off if left On and idle for 36 hours. Press the ON/OFF
button to reactivate.
Brew Lockout Feature:
NOTE: This feature is active from the factory.
This is a mechanism of the brewer which prevents the brewer from dispensing if the
BREW button is not pressed within 60 seconds of latching the brew chamber door. If
the BREW button is not pressed, within these 60 seconds, the BREW button will be
deactivated and turn yellow, disabling dispensing. To reactivate the brewer, open and
close the brew chamber door (replacing the pod if required). The BREW button will
turn green again, indicating that the brewer is ready to brew.
To deactivate this feature, push and hold the ON/OFF button for 5 seconds. (The
BREW button will momentarily flash red and white indicating that the Brew Lockout
Feature has been deactivated.)
To reactivate this feature, push and hold the ON/OFF button for 5 seconds again.
(The BREW button will momentarily flash white and green, indicating that the Brew
Lockout Feature has been activated.)
Page 8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gpod001

Table of Contents