TPS WP-Sim Manual

Multi-function simulator

Advertisement

Quick Links

Congratulations !
The WP-Sim is a complete pH, ORP, Conductivity, TDS and
Temperature simulator for TPS instruments. The WP-Sim provides an
indispensable tool for checking the operation of instruments without
sending them to the factory for service.
The manual is divided into the following sections:
1. Table of Contents
Each major section of the handbook is clearly listed. Sub-sections
have also been included to enable you to find the information you
need at a glance.
2. Introduction
The introduction has a diagram and explanation of the display and
controls of the WP-Sim. It also contains a full listing of all of the items
that you should have received with your WP-Sim. Please take the
time to read this section, as it explains some of items that are
mentioned in subsequent sections.
3. Main Section
The main section of the handbook provides complete details for
operation of the WP-Sim.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WP-Sim and is the answer not in the manual?

Questions and answers

Summary of Contents for TPS WP-Sim

  • Page 1 2. Introduction The introduction has a diagram and explanation of the display and controls of the WP-Sim. It also contains a full listing of all of the items that you should have received with your WP-Sim. Please take the time to read this section, as it explains some of items that are mentioned in subsequent sections.
  • Page 2 Page 2 TPS Pty Ltd ABN 30 009 773 371 4 Jamberoo Street Springwood, Brisbane, Australia, 4127 Phone : (07) 32 900 400 International : 61 7 32 900 400 : (07) 3808 4871 International : 61 7 3808 4871 Email : tps@tps.com.au...
  • Page 3: Table Of Contents

    Simulating Conductivity and TDS Values..........10 Simulating Temperature Values..............11 Simulating pH, ORP & Temperature for Pool Controllers...... 12 Impedance Test for pH................14 Testing the WP-Sim Battery ..............16 Changing the WP-Sim Battery ..............17 10. Warranty ...................... 18...
  • Page 4: Introduction

    Page 4 1. Introduction 1.1 WP-Sim Illustration...
  • Page 5 Page 5 pH / mV Output Selector Used to select one of a range of pH and Millivolt values. The Function switch must be set to ON or Impedance for the pH/mV output to be active. See sections 2 and 3. Conductivity / TDS Output Selector Used to select one of a range of Conductivity and TDS values.
  • Page 6: Unpacking Information

    (The battery is inside the unit.) 4. WP-Sim Handbook..............130050 Output Cables that may have been ordered with your WP-Sim … 1. pH / mV Output Cable with TPS4 plug........130132 2. Conductivity / TDS Output Cable with 5 Pin DIN plug ....130133 3.
  • Page 7: Specifications

    01,000 ppM ±5% 10,000 ppM Current temperature Can be up to Temperature inside WP-Sim unit. ±10 C offset All output values (other than Temperature) are simulated for 25 Power ..........9V Alkaline Battery for 100+ hours of continuous operation. Dimensions........187 x 110 x 51 mm Mass ...........
  • Page 8: Simulating Ph Values

    Obtain the correct pH / mV output cable for the instrument under test. Connect one end of the pH / mV output cable to the WP-Sim and the other end to the instrument under test, as per the example diagram below…...
  • Page 9: Simulating Millivolt Values

    Obtain the correct pH / mV output cable for the instrument under test. Connect one end of the pH / mV output cable to the WP-Sim and the other end to the instrument under test, as per the example diagram below…...
  • Page 10: Simulating Conductivity And Tds Values

    Connect one end of the Conductivity / TDS output cable to the WP-Sim and the other end to the instrument under test, as per the example diagram below… The WP-Sim does not need to be switched on for Conductivity or TDS output.
  • Page 11: Simulating Temperature Values

    Connect one end of the Conductivity / TDS /Temp output cable to the WP-Sim and the other end to the instrument under test, as per the example diagram below… The WP-Sim does not need to be switched on for Temperature output.
  • Page 12: Simulating Ph, Orp & Temperature For Pool Controllers

    Obtain the correct Pool Controller output cable for the instrument under test. Each end of the cable is labelled as the WP-Sim or Pool Controller end. Connect the cable to the WP-Sim and the pool controller correctly, as per the example diagram below…...
  • Page 13 BOTH readings on the display change when the pH / mV selector is changed. Please disregard the pH values when the WP-Sim is set to 650 mV, and disregard the mV reading when the WP-Sim is set to a pH value.
  • Page 14: Impedance Test For Ph

    Obtain the correct pH / mV output cable for the instrument under test. Connect one end of the pH / mV output cable to the WP-Sim and the other end to the instrument under test, as per the example diagram below…...
  • Page 15 Use the pH / mV selector to output any of the 5 simulated pH values. The readout of the instrument under test should approximately correspond to the simulated pH value selected on the WP-Sim. Variations are possible due to the current temperature and calibration settings of the instrument under test.
  • Page 16: Testing The Wp-Sim Battery

    Page 16 8. Testing the WP-Sim Battery The WP-Sim is equipped with a Battery Test function. To check the battery, set the Function switch to Battery Test. The red light on the front panel will glow brightly if the battery is OK. If the light is very dim or does...
  • Page 17: Changing The Wp-Sim Battery

    Do not lose the nylon washers, as these form a part of the waterproof seal when the screws are replaced. Replace the battery with a new alkaline 9V battery. Re-fit the rear of the WP-Sim and replace the Instrument Case Screws.
  • Page 18: Warranty

    TPS Pty. Ltd. has a fine reputation for prompt and efficient service. In just a few days, our factory service engineers and technicians will examine and repair your equipment to your full satisfaction.
  • Page 19 Page 19 To obtain this service, please follow this procedure Return the instrument AND ALL SENSORS to TPS freight pre-paid and insured in its original packing or suitable equivalent. INSIST on a proof of delivery receipt from the carrier for your protection in the case of shipping claims for transit loss or damage.