Gigabit Business Router
Connecting to the Grounding Bar
Use the grounding bar
If the device is installed in the Equipment Room, where a grounding bar is available, you
are recommended to connect the device to the grounding bar as shown in the following
figure.
Figure 3-2

Equipotential Bonding

Equipotential Bonding is the practice of intentionally electrically connecting all earthed
systems to the same grounding grid or connecting the grounding grids of all the
earthed systems together through the ground or overground metal so as to create
an earthed equipotential zone. When lightning occurs, the high voltage produced by
lightning current in all systems will meanwhile exist in their ground cables, and thus all
ground cables have the same electrical potential and basically eliminate the electric
strikes between the systems.
The figure below illustrates how to practice equipotential bonding in a network.
12
Lightning Protection
Connecting to the Grounding Bar
Device (Rear Panel)
Ground Cable
Note:
The grounding bar and ground cable are not provided with our product. If
needed, please self purchase them.
100-240V~ 50/60Hz 0.2A
Grounding Terminal
Grounding Bar