  • Page 1 Business Networking Solution Installation Guide Gigabit Business Router TL-ER5120/TL-ER6120...
  • Page 3 Conventions • Some models featured in this guide may be unavailable in your country or region. For local sales information, visit http://www.tp-link.com. • The figures in Chapter 2 to Chapter 4 are for demonstration purposes only. Your switch may differ in appearance from that depicted.
  • Page 4: Table Of Contents

    Contents Chapter 1 Introduction ——————————— 01 Product Overview ............01 Appearance ...............01 Chapter 2 Installation ———————————— 04 Package Contents ............04 Safety Precautions ............04 Installation Tools ..............06 Product Installation ............07 Chapter 3 Lightning Protection ——————— 09 Cabling Reasonably............09 Connect to Ground ............11 Equipotential Bonding ...........12 Use Lightning Arrester ..........13 Chapter 4 Connection ———————————...
  • Page 5: Chapter 1 Introduction

    Appearance Front Panel ■ The front panel of TL-ER5120 is shown as the following figure. Figure 1-1 Front Panel of TL-ER5120 LEDs Status...
  • Page 6 Gigabit Business Router Interface Description Interface Description The WAN port is designed to connect the router to a DSL/Cable modem or Ethernet by the RJ45 cable The LAN port is designed to connect the router to the local PCs or switches by the RJ45 cable Reset Use the button to restore the router to the factory defaults.
  • Page 7 SYS LED goes out, release the Reset button. If the SYS LED is flashing with a high frequency about two or three seconds, it means the router is restored successfully. Rear Panel ■ The rear panel of TL-ER5120/TL-ER6120 is shown as the following figure. Figure 1-3 Rear Panel 100-240V~ 50/60Hz 0.2A...
  • Page 8: Chapter 2 Installation

    Gigabit Business Router Chapter 2 Installation Package Contents Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Router This Installation Guide One Power Cord Two mounting brackets and the fittings Safety Precautions To avoid any device damage and bodily injury caused by improper use, please observe...
  • Page 9 Gigabit Business Router Temperature/Humidity Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device.
  • Page 10: Installation Tools

    Gigabit Business Router Lightening Protection Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20,000℃. As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken.
  • Page 11: Product Installation

    Gigabit Business Router Note: These tools are not provided with our product. If needed, please self purchase them. Product Installation Desktop Installation ■ To install the device on the desktop, please follow the steps below: 1. Set the device on a flat surface strong enough to support the entire weight of the device with all fittings.
  • Page 12 Gigabit Business Router Figure 2-6 Rack Installation Rack Caution: Please set 5~10cm gaps around the device for air circulation. ■ Please avoid any heavy thing placed on the device. ■ Please mount devices in sequence from the bottom to top of the rack and ensure ■...
  • Page 13: Chapter 3 Lightning Protection

    Gigabit Business Router Chapter 3 Lightning Protection Cabling Reasonably In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices. Note: It’s not recommended using Ethernet cables outdoors.
  • Page 14 Gigabit Business Router Requirements for Cabling Indoors ■ When cabling indoors, keep a certain distance away from the devices that may cause high-frequency interferences, such as down-conductor cable, powerline, power transformer and electromotor. The main cable should be paved in the metal raceway of the access shaft. When ■...
  • Page 15: Connect To Ground

    Gigabit Business Router Parallel cabling >5kVA One is in the grounded metal raceway or metal pipe powerline The both are in the grounded metal raceway or metal pipe Device Min Distance (m) Switch case 1.00 Transformer room 2.00 Elevator tower 2.00 Air-conditioner room 2.00...
  • Page 16: Equipotential Bonding

    Gigabit Business Router Connecting to the Grounding Bar ■ Use the grounding bar If the device is installed in the Equipment Room, where a grounding bar is available, you are recommended to connect the device to the grounding bar as shown in the following figure.
  • Page 17: Use Lightning Arrester

    Gigabit Business Router Figure 3-3 Equipotential Bonding Grounding Terminal Equipotential Bonding Cable Ground Cable Grounding Bar When equipotential bonding, please note that the cable should be copper wrapped Kelly with its area being 6mm at least. The shorter cable the better, and use a grounding bar to establish an equipotential bonding point.
  • Page 18 Gigabit Business Router When purchasing or using a signal lightning arrester, please observe the following rules: The port rate of the signal lightning arrester should match the rate of the desired port ■ on the device. If it is not matched, this signal lighting arrester will not work. Purchase a standard lightning arrester.
  • Page 19: Chapter 4 Connection

    Gigabit Business Router Chapter 4 Connection WAN Port Please connect the WAN port of the router to the interface provided by ISP via Ethernet cable. LAN Port Connect a LAN port of the router to the computer by RJ45 cable as the following figure shows.
  • Page 20: Power On

    Gigabit Business Router Power On Plug the negative connector of the provided power cord into the power socket of the device, and the positive connector into a power outlet as the following figure shows. Figure 4-2 Connecting to Power Supply Note: The figure is to illustrate the application and principle.
  • Page 21: Chapter 5 Configuration

    Gigabit Business Router Chapter 5 Configuration Preparations 1. Connect a PC to a LAN port of the router with a RJ45 cable properly. 2. If your computer is configured with a fixed IP, change it to "Obtain an IP address automatically".
  • Page 22 Gigabit Business Router 3. Use the username and password set above to log in to the webpage. Figure 5-3 Log in to the Webpage 4. After a successful login, the main page will appear as in the figure below, and you can configure the function by clicking the setup menu on the left side of the screen.
  • Page 23: Appendix A Troubleshooting

    Gigabit Business Router Appendix A Troubleshooting Q1. What should I do if I forget the username and password for the router's web management page? Please restore the router to factory defaults. The default management address of the router is http://192.168.0.1. The default username and password are both admin. All current settings will be cleared once the router is restored.
  • Page 24: Appendix B Hardware Specifications

    Gigabit Business Router Appendix B Hardware Specifications Item Content Standards IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x, TCP/IP, DHCP, ICMP, NAT, PPPoE, SNTP, HTTP, DNS, L2TP/PPTP/IPSec (for TL-ER6120) Transmission Medium 10Base-T: UTP/STP of Cat. 3 or above(≤100m) 100Base-TX: UTP/STP of Cat. 5 or above(≤100m) 1000Base-T: UTP/STP of Cat.5e or above(≤100m) LEDs PWR, SYS, WAN, Speed...
  • Page 25 FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
  • Page 26 この装置は、 クラスA情報技術装置です。 この装置を家庭環境で使用すると電波妨害を引き起こすことがあ ります。 この場合には使用者が適切な対策を講ずるよう要求されることがあります。      VCCI-A BSMI Notice 安全諮詢及注意事項 1) 請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。 2) 清潔本產品之前請先拔掉電源線。 請勿使用液體、 噴霧清潔劑或濕布進行清潔。 3) 注意防潮, 請勿將水或其他液體潑灑到本產品上。 4) 插槽與開口供通風使用, 以確保本產品的操作可靠並防止過熱, 請勿堵塞或覆蓋開口。 5) 請勿將本產品置放於靠近熱源的地方。 除非有正常的通風, 否則不可放在密閉位置中。 6) 請不要私自打開機殼, 不要嘗試自行維修本產品, 請由授權的專業人士進行此項工作。 7) 此為甲類資訊技術設備, 于居住環境中使用時, 可能會造成射頻擾動, 在此種情況下, 使用者會被要求採取某 些適當的對策。 Industry Canada Statement CAN ICES-3 (A)/NMB-3(A) Explanation of the symbols on the product label Symbol Explanation...
  • Page 28 GNU General Public License (“GPL”). As applicable, the terms of the GPL and any information on obtaining access to the respective GPL Code used in TP-Link products are available to you in GPL-Code-Centre under (http:// www.tp-link.com/en/support/gpl/). The respective programs are distributed WITHOUT ANY WARRANTY and are subject to the copyrights of one or more authors.