MAINTENANCE AND INSPECTION INSTRUCTIONS (CONTINUED)
Belts
Check belt tension every 3 months. Adjust belt tension to allow 3/8 inch to 1/2 inch deflection with normal
thumb pressure. Also, align belts using a straight edge against the face of the flywheel and touching the
rim on both sides of the face. The belts should be parallel to this straight edge (see Figure 11). Dimension A
should be the same as B and C to ensure proper alignment of the belts.
Slots in the bed-plate allow for sliding the motor back and forth to adjust belt tension.
Air Compressor
Figure 11 - Top View
Removing Belt Guard
clips and replace if damaged or if clip can be removed without a tool.
Removing Retaining Clips
1.
Using crescent wrench on pliers, rotate clip 90°.
2.
Pull clip out and away from beltguard.
3.
Reverse process to reinstall after inspecting the clip.
Storage
If compressor is to be stored for a short period of time, make sure
that it is stored in a normal position and in a cool protected area.
Maintenance Schedule
OPERATION
Check Safety Valve
Drain Tank (see Figure 8)
Check Oil Level
Clean or Change Air Filter
Check Intercooler
Clean Unit Components
Check Belt Tightness
Change Oil (see Figure 6)
Lock out and tag the power then release all pressure from the tank to prevent unexpected
movement of the unit.
A
Flywheel
Straight Edge
When removing belt guard front to
inspect or replace belts, inspect plastic retaining
Motor
Drive
Motor
Pulley
B
Setscrew
Figure 12
DAILY
15
C
1
2
MONTHLY
3 MONTHS